Detectability of catheters on bedside chest radiographs: comparison between liquid crystal display and high-resolution cathode-ray tube monitors.

机译:床边胸部X射线照片上的导管可检测性:液晶显示器和高分辨率阴极射线管监视器之间的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode-ray tube (CRT) monitor in the detection of simulated support catheters on bedside chest radiographs. MATERIALS AND METHODS: The ethics committee did not require approval or patient informed consent when this study began. Because of a change in regulations, before images were acquired the nature of the study and procedures were explained to patients or their relatives, and consent was then obtained. A total of 131 catheter fragments (12-14 per radiograph) were superimposed over 10 anteroposterior bedside chest radiographs obtained with storage phosphor technology. Images were displayed on an LCD monitor (1536 x 2048 matrix) and a CRT monitor (2048 x 2560 matrix). Five radiologists independently located the catheter fragments and rated their confidence in detection with bright and subdued ambient light. A two-way analysis of variance and the Friedman test were usedfor statistical analysis. RESULTS: There was no significant difference for either display type with respect to correctly detected catheter fragments (mean sensitivity, 56.6% and 56.0% for the CRT and the LCD monitors, respectively, with bright light and 61.2% for both monitors with subdued light). With both display types, detection rate with bright light decreased significantly (P < .05). False-positive rates and confidence ratings were not significantly affected by monitor type or ambient light. CONCLUSION: In a study with simulation of clinical conditions, performance of the LCD monitor and high-resolution CRT monitor for detection of support catheters on bedside chest radiographs was equivalent. With both displays, detection performance was equally reduced with bright ambient light.
机译:目的:将观察者的表现与平板液晶显示器(LCD)监视器和高分辨率灰度阴极射线管(CRT)监视器进行比较,以检测床旁胸部X光片上的模拟支持导管。材料与方法:这项研究开始时,伦理委员会不需要批准或患者知情同意。由于法规的变化,在获取图像之前,先向患者或其亲属说明研究的性质和步骤,然后获得同意。将总共​​131个导管碎片(每个X射线照片12-14个)叠加在通过存储荧光粉技术获得的10个床前前后位胸部X射线照片上。图像显示在LCD监视器(1536 x 2048矩阵)和CRT监视器(2048 x 2560矩阵)上。五名放射科医生独立定位了导管碎片,并用明亮而柔和的环境光评估了他们对检测的信心。采用方差的双向分析和弗里德曼检验进行统计分析。结果:两种显示类型在正确检测到的导管碎片方面均无显着差异(CRT和LCD监视器的平均灵敏度分别为56.6%和56.0%,强光监视器和柔光的两个监视器均为61.2%)。 。在两种显示类型下,亮光的检测率均显着降低(P <.05)。监视器类型或环境光对假阳性率和置信度的影响不明显。结论:在一项模拟临床情况的研究中,LCD监视器和高分辨率CRT监视器在床旁胸部X线照片上检测支撑导管的性能相当。对于这两种显示器,明亮的环境光都会同样降低检测性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号