Radiochemical purity is an important quality parameter for radiopharmaceuticals. In this study, the radiochemical purity of 2090 samples out of 7000 routine preparations of 20 different 99Tcm radiopharmaceuticals was tested using standard methods over a period of more than 7 years. The mean radiochemical purity was 96.92% (standard deviation = 6.71%). Seventy-four preparations failed to meet radiochemical purity limits; that is, 3.54% of all preparations tested or 1.06% of all preparations in the observation period. The reasons for substandard preparations were mainly related to laboratory-specific conditions. The introduction of a dedicated quality control protocol allowed the elimination of many sources of labelling failures and could reduce the number of administered preparations with an insufficient radiochemical purity. We stress the need for quality control in the preparation of radiopharmaceuticals and provide original radiochemical purity values of routinely prepared 99Tcm radiopharmaceuticals.
机译:放射化学纯度是放射性药物的重要质量参数。在这项研究中,使用标准方法测试了20种不同的99Tcm放射性药物的7000种常规制剂中的2090个样品的放射化学纯度,历时7年以上。平均放射化学纯度为96.92%(标准偏差= 6.71%)。七十四种制剂未达到放射化学纯度极限;也就是说,在观察期内,测试的所有制剂为3.54%,或者为所有制剂的1.06%。制备不合格的原因主要与实验室特定条件有关。引入专用的质量控制方案可以消除许多标记失败的原因,并可以减少放射化学纯度不足的制剂的使用量。我们强调放射性药物制备过程中需要进行质量控制,并提供常规制备的99Tcm放射性药物的原始放射化学纯度值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号