This study was undertaken to assess the correlation between a self-administered, adapted Six Minute Walk Test (the Home-Heart-Walk) and the standard Six Minute Walk Test based on the American Thoracic Society guideline. A correlational study was conducted at a university campus in Sydney, Australia. Thirteen healthy volunteers underwent the Home-Heart-Walk and the standard Six Minute Walk Test on a single occasion. The distance that participants walked during the two tests was assessed using Pearson's correlation. The correlation between the Home-Heart-Walk and the Six Minute Walk Test distance was 0.81. The Home-Heart-Walk distance was highly correlated to the standard Six Minute Walk Test distance in this study. This relationship provides confidence for further research in populations to facilitate monitoring and evaluation.
机译:进行这项研究是为了评估自我管理的,适应性的六分钟步行测试(家庭心脏步行)与基于美国胸科学会指南的标准六分钟步行测试之间的相关性。相关研究在澳大利亚悉尼的大学校园内进行。 13名健康志愿者一次接受了“家庭心脏步行”和标准的6分钟步行测试。使用皮尔森相关性评估参与者在两次测试中行走的距离。家庭心脏步行和六分钟步行测试距离之间的相关性是0.81。在这项研究中,居家步行距离与标准的六分钟步行测试距离高度相关。这种关系为在人口中开展进一步研究以促进监测和评估提供了信心。