首页> 外文期刊>Materials science & engineering, C. Materials for Biogical applications >A high sensitive label-free immunosensor for the determination of human serum IgG using overoxidized polypyrrole decorated with gold nanoparticle modified electrode
【24h】

A high sensitive label-free immunosensor for the determination of human serum IgG using overoxidized polypyrrole decorated with gold nanoparticle modified electrode

机译:一种高灵敏度的无标记免疫传感器,使用修饰有金纳米粒子修饰电极的过氧化聚吡咯测定人血清IgG

获取原文
获取原文并翻译 | 示例
           

摘要

Herein, an electrochemical human immunoglobulin G (HIgG) immunosensor was fabricated using overoxidized polypyrrole decorated with gold nanoparticle (OPPy-Au-nano) modified screen printed electrode (OPPy-Au-nano/SPE). The results clearly demonstrate that OPPy-Au-nano film is very permeable to [Fe(CN)(6)](3-/4-). Therefore, the fabrication of immunosensor based on permeability of OPPy-Au-nano film to [Fe(CN)(6)](3-/4-) probe is a novel strategy for the fabrication of label free electrochemical immunosensor. The electrochemical impedance spectroscopy (EIS) techniques are used for the determination of HIgG in the concentration range 0.5 to 125.0 ng ml(-1) and with a limit of detection of 0.02 ng mL(-1), respectively. (C) 2015 Elsevier B.V. All rights reserved.
机译:本文中,使用装饰有金纳米粒子(OPPy-Au-nano)修饰的丝网印刷电极(OPPy-Au-nano / SPE)的过氧化聚吡咯制备了电化学人免疫球蛋白G(HIgG)免疫传感器。结果清楚地表明,OPPy-Au-nano膜对[Fe(CN)(6)](3- / 4-)具有很好的渗透性。因此,基于OPPy-Au-nano膜对[Fe(CN)(6)](3- / 4-)探针的渗透性制造免疫传感器是一种无标记电化学免疫传感器的新型制备策略。电化学阻抗谱(EIS)技术用于测定HIgG的浓度范围为0.5至125.0 ng ml(-1),检出限分别为0.02 ng mL(-1)。 (C)2015 Elsevier B.V.保留所有权利。