首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >AuNPs/PpPD/PEDOT:PSS-Fc modified screen-printed carbon electrode label-free immunosensor for sensitive and selective determination of human serum albumin
【24h】

AuNPs/PpPD/PEDOT:PSS-Fc modified screen-printed carbon electrode label-free immunosensor for sensitive and selective determination of human serum albumin

机译:AUNPS / PPPD / PEDOT:PSS-FC改性丝网印刷碳电极标记免疫传感器,用于敏感和选择性测定人血清白蛋白

获取原文
获取原文并翻译 | 示例
       

摘要

A novel, label-free immunosensor was fabricated for human serum albumin (HSA) detection in urine and human serum. A screen-printed carbon electrode (SPCE) was modified with a poly (3,4-ethylenedioxythiophene): poly (styrenesulfonate) and ferrocene nanocomposite (PEDOT: PSS-Fc) which was first coated with poly(para-phenylenediamine) (PpPD) and then functionalized with gold nanoparticles (AuNPs). Anti-human serum albumin (anti-HSA) was immobilized on the AuNPs/PpPD layer by direct chemisorption. HSA sample concentration was determined from the change in the Fc oxidation peak current caused by the formation of HSA/anti-HSA immunocomplex. Under optimal conditions, the sensor's output was linear from 1.0 x 10(-9) to 1.0 x 10(-2) mu g mL(-1) with a detection limit of 5.4 x 10(-10) mu g mL(-1). Modification with AuNPs increased the amount of anti-HSA that could be immobilized on the surface of the electrode and as a result, sensitivity increased 10.1 times. The developed immunosensor exhibited good reusability (sensitivity >90% after 8 cycles of binding-rebinding), good stability (90% sensitivity within 30 days), excellent reproducibility (RSD of <7.6%, n = 6) and high specificity. Applied to detect HSA in urine and human serum, the sensor produced results that agreed well with results obtained from the standard immunoturbidimetric method (P > 0.05). The excellent performance of the sensor confirmed its utility in clinical diagnosis.
机译:为尿液和人血清中的人血清白蛋白(HSA)检测制备了一种新型的免疫传感器。用聚(3,4-亚乙二氧基噻吩)(苯乙烯磺酸盐)和二茂铁纳米复合材料(PETOT:PSS-FC)改性丝网印刷的碳电极(SPCE),其首先用聚(para-苯二胺)(PPPD)涂覆然后用金纳米颗粒(AUNP)官能化。通过直接化学吸附在AUNPS / PPPD层上固定抗人血清白蛋白(抗HSA)。从由HSA /抗HSA免疫混合物形成引起的Fc氧化峰电流的变化确定HSA样品浓度。在最佳条件下,传感器的输出从1.0×10(-9)到1.0×10(-2)mu g ml(-1)的线性,检测限为5.4×10(-10)mu g ml(-1 )。随着AUNP的修饰增加了可以固定在电极表面上的抗HSA的量,结果,灵敏度增加了10.1倍。发育的免疫传感器具有良好的可重用性(敏感性> 90%后的结合重新凝固后的90%),良好的稳定性(30天内敏感性90%),优异的再现性(RSD为<7.6%,n = 6)和高特异性。应用于检测尿液和人血清中的HSA,传感器产生的结果与标准免疫浊法获得的结果相同(P> 0.05)。传感器的优异性能证实其在临床诊断中的效用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号