AIMS: This article aims to identify quality control (QC) best practice, to review published QC audits in order to identify how closely good practice is followed, and to carry out a market survey of the software features that support QC offered by urodynamics machines available in the UK. METHODS AND RESULTS: All UK distributors of urodynamic systems were contacted and asked to provide information on the software features relating to data quality of the products they supply. The results of the market survey show that the features offered by manufacturers differ greatly. Automated features, which can be turned off in most cases, include: cough recognition, detrusor contraction detection, and high pressure alerts. There are currently no systems that assess data quality based on published guidelines. A literature review of current QC guidelines for urodynamics was carried out; QC audits were included in the literature review to see how closely guidelines were being followed. This review highlights the fact that basic QC is not being carried out effectively by urodynamicists. CONCLUSION: Based on the software features currently available and the results of the literature review there is both the need and capacity for a greater degree of automation in relation to urodynamic data quality and accuracy assessment. Some progress has been made in this area and certain manufacturers have already developed automated cough detection.
机译:目的:本文旨在确定质量控制(QC)最佳实践,审查已发布的QC审核,以查明遵循良好实践的程度,并对支持urodynamics机器提供的QC的软件功能进行市场调查。在英国。方法和结果:与所有尿动力学系统的英国分销商联系并被要求提供有关其所提供产品的数据质量的软件功能信息。市场调查的结果表明,制造商提供的功能差异很大。在大多数情况下,可以关闭的自动功能包括:咳嗽识别,逼尿肌收缩检测和高压警报。当前,没有基于发布的准则评估数据质量的系统。对现行的尿动力学QC指南进行了文献综述。文献审查中包括了质量控制审核,以查看指南的遵循程度。这篇评论强调了一个事实,即尿动力学专家没有有效地进行基本的质量控制。结论:根据当前可用的软件功能和文献综述的结果,对于尿动力学数据质量和准确性评估,需要更大程度的自动化程度和能力。在这一领域已经取得了一些进展,某些制造商已经开发了自动咳嗽检测仪。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号