首页> 外文期刊>Neurourology and urodynamics. >Short-term test-retest reproducibility of urethral pressure profilometry in women with urodynamic stress incontinence with and without detrusor overactivity.
【24h】

Short-term test-retest reproducibility of urethral pressure profilometry in women with urodynamic stress incontinence with and without detrusor overactivity.

机译:尿动力学压力性尿失禁伴或不伴逼尿肌过度活动的女性,尿道压力轮廓测定的短期重测可重复性。

获取原文
获取原文并翻译 | 示例
           

摘要

AIMS: To determine and compare reproducibility of urethral pressure profilometry (UPP) in women with urodynamic stress incontinence (USI) alone or together with detrusor overactivity (DO). METHODS: Women were recruited from a urodynamic clinic diagnosed with USI using dual channel cystometry. UPP was performed with the technique described by Hilton and Stanton [Hilton P, Stanton SL. Br J Obstet Gynaecol 90:919-33,1983]. Different urethral function parameters were obtained. Two weeks later the tests were repeated. The precision and bias of the tests were measured using the Bland and Altman method [Bland JM, Altman DG. Lancet 1:307-10,1986]. The coefficient of variation (CV) value allowed direct comparison of repeatability of each test, with a lower value indicating less variation. RESULTS: Thirty-one women completed both visits. Fourteen women had USI, the other 17 diagnosed with USI with DO at the end of two visits. There was no significant difference between visits for all the parameters for all women recruited. The most reproducible parameter was functional urethral length and maximum urethral pressure as demonstrated by lowest CV. The women with USI group had more reproducible UPP parameters than those with mixed USI and DO in all parameters apart from pressure transmission ratio in Quartiles 2, 3, and 4. However, there was no significant difference between the two diagnostic groups. CONCLUSIONS: Tests of urethral function in urethral pressure profilometry are shown to have poor reproducibility in women with USI, but limit of agreement may be acceptable in some of the tests. The with-in subject CV appears to be higher in women with mixed USI and DO compared to USI only.
机译:目的:确定和比较尿动力学压力性尿失禁(USI)或与逼尿肌过度活动症(DO)一起使用的妇女尿道压力轮廓测定法(UPP)的可重复性。方法:采用双通道膀胱测压法从诊断为USI的尿流动力学诊所招募女性。 UPP用Hilton和Stanton [Hilton P,Stanton SL。 Br J Obstet Gynaecol 90:919-33,1983]。获得了不同的尿道功能参数。两周后,重复测试。使用Bland和Altman方法[Bland JM,Altman DG。柳叶刀1:307-10,1986]。变异系数(CV)值可以直接比较每个测试的可重复性,较低的值表示变异较小。结果:31名妇女完成了两次访问。两次访视结束时,有14名妇女患有USI,另外17名妇女被确诊为USI伴有DO。在所有征募妇女的所有参数之间,访视之间没有显着差异。最可重复的参数是功能性尿道长度和最大尿道压力,如最低CV所示。与USI和DO混合的女性相比,USI组的女性在所有参数上均具有更高的可重现UPP参数,除了四分位数2、3和4中的压力传递比。但是,两个诊断组之间没有显着差异。结论:尿道压力轮廓测定中的尿道功能测试显示出对USI妇女的可重复性较差,但是在某些测试中一致性限制是可以接受的。与仅USI相比,混合USI和DO的女性的受试对象CV似乎更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号