...
首页> 外文期刊>Neurotoxicology >P300 of auditory event related potentials in occupational chronic solvent encephalopathy.
【24h】

P300 of auditory event related potentials in occupational chronic solvent encephalopathy.

机译:职业性慢性溶剂性脑病的听觉事件相关电位的P300。

获取原文
获取原文并翻译 | 示例

摘要

This retrospective study characterized the P300 component of the auditory event related potential (ERP) and assessed its diagnostic value in occupational chronic solvent encephalopathy (CSE). The P300 was recorded on 86 CSE patients by the classical oddball paradigm. In addition to the laboratory's reference values, we used an age and education matched control group that consisted of 104 blue-collar workers with no known occupational solvent exposure. The association of P300 values with solvent exposure indices, major depression, alcohol consumption, and neuropsychological parameters was studied. The P300 amplitude was lower in CSE patients (mean 7.5 microV; S.D. 3.6) compared to laboratory controls (mean 11.8 microV; S.D. 4.1; F(1,167)=24.4; p<0.001, 95% CI -4.4 to -1.8) and to matched controls (mean 9.0 microV; S.D. 4.0; p=0.007, 95% CI -2.6 to -0.4). The P300 latency was longer in the CSE patients (mean 358 ms; S.D. 28) compared to laboratory controls (mean 339 ms; S.D. 19, F(1,167)=7.6, p=0.006, 95% CI 3.12-18.7) but did not differ from matched controls (mean 358 ms; S.D. 22; p=0.947, 95% CI -7.4 to 6.9). The solvent exposure indices, major depression, or alcohol consumption did not associate with the P300 values. The P300 amplitude correlated positively with the Digit Symbol test. All the amplitude values in the patient group and in the matched control group were classified as normal (i.e. age corrected mean+/-2.5S.D.) against the laboratory's reference values. Thirty percent of the latencies in the CSE patient group and 26% in the matched control group were classified as abnormal. At group level, the decreased P300 amplitudes in CSE patients may reflect solvent-related pathophysiology. However, the P300 measured with the classical oddball paradigm does not seem to be sensitive at individual level or useful in clinical practice.
机译:这项回顾性研究表征了听觉事件相关电位(ERP)的P300成分,并评估了其在职业性慢性溶剂性脑病(CSE)中的诊断价值。 P300用经典的奇数球范例记录了86位CSE患者。除了实验室的参考值外,我们还使用了由年龄和文化程度相匹配的对照组,该对照组由104名蓝领工人组成,他们没有已知的职业溶剂暴露。研究了P300值与溶剂暴露指数,严重抑郁,酒精消耗和神经心理学参数的关系。与实验室对照(平均11.8 microV; SD 4.1; F(1,167)= 24.4; p <0.001,95%CI -4.4至-1.8)相比,CSE患者的P300幅度较低(平均7.5 microV; SD 3.6)。匹配的对照(平均值9.0 microV; SD 4.0; p = 0.007,95%CI -2.6至-0.4)。与实验室对照组相比(平均339 ms; SD 19,F(1,167)= 7.6,p = 0.006,95%CI 3.12-18.7),CSE患者的P300潜伏期更长(平均358毫秒; SD 28)。与配对对照有所不同(平均值358毫秒; SD 22; p = 0.947,95%CI -7.4至6.9)。溶剂暴露指数,严重抑郁或酒精消耗与P300值不相关。 P300振幅与数字符号测试呈正相关。相对于实验室的参考值,将患者组和匹配的对照组中的所有振幅值归类为正常值(即,年龄校正后的平均值+/- 2.5S.D。)。 CSE患者组中30%的延迟和配对对照组中26%的延迟被分类为异常。在组水平上,CSE患者的P300振幅降低可能反映了溶剂相关的病理生理。但是,用经典奇数球范式测量的P300在个体水平上似乎并不敏感,也没有用于临床实践。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号