...
首页> 外文期刊>Cancer: A Journal of the American Cancer Society >The Emerging Technique of Electromagnetic Navigation Bronchoscopy-Guidecl Fine-Needle Aspiration of Peripheral Lung Lesions Promising Results in 50 Lesions
【24h】

The Emerging Technique of Electromagnetic Navigation Bronchoscopy-Guidecl Fine-Needle Aspiration of Peripheral Lung Lesions Promising Results in 50 Lesions

机译:电磁导航支气管镜检查-指导性周围周围肺病变细针抽吸术的新兴技术有望在50个病变中取得成功

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Literature on the diagnostic yield of electromagnetic navigation bronchoscopy (ENB) with ENB-guided fine-needle aspiration (ENB-FNA) in peripheral lung lesions (PLLs) that measure <2 cm is scarce. Data on the diagnostic yield of ENB-FNA for PLLs when performed in conjunction with positron emission tomography-computed tomography (PET-CT), rapid on-site evaluation (ROSE), ENB-guided bronchial brushing (ENB-BB), and ENB-guided transbronchial biopsy (ENB-TBx) is also limited. In this study, the authors evaluated their experience with ENB-FNA performed in conjunction with all 4 modalities: PET-CT, ROSE, ENB-BB, and ENB-TBx. METHODS: ENB-FNA and other tests over a 2-year-period (from July 2011 to July 2013) were retrospectively reviewed. RESULTS: There were 50 PLLs from 40 patients, and the mean lesion size (available for 45 PLLs) was 2.6 cm: these included 24 PLLs that measured < 2 cm and 21 PLLs that measured >2.0 cm. The ENB-FNA diagnosis was malignant in 17 lesions, atypical in 1 lesion, benign in 31 lesions, and nondiagnostic in 1 lesion. On the basis of lesion size, the diagnostic yield of PLLs was 87% in lesions < 2 cm and 100% in lesions > 2.0 cm (P = 0.5; not significant). Follow-up available in 49 of 50 PLLs from 39 patients had an overall diagnostic yield of 94% for ENB-FNA. The diagnostic yield of PET-CT (available in 31 of 50 PLLs) and of ENB-BB and ENB-TBx (available in 40 of 50 PLLs) in conjunction with ENB-FNA was 61% and 95%, respectively. ROSE was performed in 46 of 50 PLLs: the overall sensitivity of ROSE and ENB-FNA was 85% and 89.4%, respectively, and their specificity was 96.5% and 100%, respectively. There were no procedure-related complications. CONCLUSIONS: The high overall diagnostic yield of 94% and fewer complications make ENB-FNA a useful modality for the assessment of PLLs. In this study, ROSE was useful, whereas PET-CT, ENB-BB, and ENB-TBx were not useful in the evaluation of PLLs.
机译:背景:关于在小于2 cm的周围肺病变(PLL)中进行ENB引导的细针抽吸(ENB-FNA)的电磁导航支气管镜(ENB)的诊断率的文献很少。与正电子发射断层扫描计算机断层扫描(PET-CT),快速现场评估(ROSE),ENB引导的支气管刷洗(ENB-BB)和ENB结合使用时,有关PLL的ENB-FNA诊断产率的数据引导的经支气管活检(ENB-TBx)也受到限制。在这项研究中,作者评估了他们在ENB-FNA结合所有4种方式进行的经验:PET-CT,ROSE,ENB-BB和ENB-TBx。方法:回顾性地回顾了2年(从2011年7月至2013年7月)的ENB-FNA和其他测试。结果:40名患者中有50个PLL,平均病变大小(适用于45个PLL)为2.6 cm:其中包括24个PLL的尺寸小于2 cm和21个PLL的尺寸大于2.0 cm。 ENB-FNA诊断为17处恶性,1处为非典型,31处为良性,1处未诊断。根据病变大小,在<2 cm的病变中,PLL的诊断率为87%,在> 2.0 cm的病变中为100%(P = 0.5;不显着)。来自39位患者的50个PLL中有49个的随访结果显示,ENB-FNA的总诊断率为94%。与ENB-FNA结合使用的PET-CT(在50个PLL中有31个可用)和ENB-BB和ENB-TBx(在50个PLL中有40个可用)的诊断率分别为61%和95%。在50个PLL中的46个中执行了ROSE:ROSE和ENB-FNA的总灵敏度分别为85%和89.4%,其特异性分别为96.5%和100%。没有与手术相关的并发症。结论:94%的高总诊断率和较少的并发症使ENB-FNA成为评估PLL的有用方式。在这项研究中,ROSE是有用的,而PET-CT,ENB-BB和ENB-TBx在PLL的评估中没有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号