首页> 外文期刊>Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA >MRI assessment of the structural labrum integrity after Bankart repair using knotless bio-anchors.
【24h】

MRI assessment of the structural labrum integrity after Bankart repair using knotless bio-anchors.

机译:使用无结生物锚定器对Bankart修复后的结构唇唇完整性进行MRI评估。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Adequate labral restorations after Bankart repair have been demonstrated in cadaver models for knot-tying and knotless anchors and in vivo by magnetic resonance imaging for knot tying. The influence of glenoidal bio-degradation on clinical outcome, and conclusions regarding drill hole enlargement and foreign body reactions remain controversial. METHODS: The labrum was analyzed in magnetic resonance images for 37 consecutive patients with Bankart repair using knotless PLLA anchors and for 31 volunteers as radiologic controls. The labrum was assessed regarding slope, height index (quotient between labral height to the glenoid height), and labrum morphology in axial and coronal T2 images. Glenoidal bio-degradation was graded in terms of the drill hole configuration in T1 images and the corresponding osseous reaction in T2 images. Constant-Murley, Walch-Duplay, and Rowe scoring were carried out preoperatively and at follow-up. RESULTS: At 15 months after arthroscopy, the anterior slope (24.8 degrees ), height index (3.0), inferior slope (25.4 degrees ), and height index (2.5) were not significantly different from control values. Morphologic analysis revealed significant changes in the Bankart group (P < 0.05) that were influenced by the number of preoperative dislocations. Bio-degradation proceeded slowly with no evidence of drill hole enlargement. Osseous reactions were significantly greater in inferior compared to superior implants. The clinical scores were excellent and were not influenced by bio-degradation. CONCLUSIONS: Knotless anchors facilitate labral restoration that is comparable to the knot-tying approach. Bio-degradation proceeds slowly without clinical or radiologic evidence of foreign body reactions. LEVEL OF EVIDENCE: III.
机译:目的:Bankart修复后的足部修复已在尸体模型中用于打结和无打结锚钉以及在体内通过磁共振成像进行打结进行了证明。关节盂生物降解对临床结果的影响,以及有关钻孔扩大和异物反应的结论仍存在争议。方法:利用磁共振成像技术分析了连续37例使用无结PLLA锚钉进行Bankart修复的患者和31名作为放射学对照的志愿者的磁共振图像。在轴向和冠状T2图像中,评估了唇肌的坡度,高度指数(唇肌高度与盂盂高度之间的商)以及唇肌形态。根据T1图像中的钻孔配置和T2图像中相应的骨反应,对类盂生物降解进行了分级。术前和随访时进行了Constant-Murley,Walch-Duplay和Rowe评分。结果:关节镜检查后15个月,前斜度(24.8度),身高指数(3.0),下斜度(25.4度)和身高指数(2.5)与对照值无显着差异。形态学分析显示,Bankart组的术前脱位数量受到显着变化(P <0.05)。生物降解进行缓慢,没有钻孔扩大的迹象。与优越的植入物相比,下部的骨反应明显更大。临床得分极好,不受生物降解的影响。结论:无结锚可以促进唇的修复,这与结扎方法相当。没有生物或异物反应的临床或放射学证据,生物降解过程缓慢进行。证据级别:III。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号