Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform).

机译:影像引导放射治疗的临床应用IGRT(在Varian OBI平台上)。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Image-guided radiation therapy (IGRT) can be used to measure and correct positional errors for target and critical structures immediately prior to or during treatment delivery. Some of the most recent available methods applied for target localization are: transabdominal ultrasound, implanted markers with in room MV or kV X-rays, optical surface tracking systems, implantable electromagnetic markers, in room CT such as kVCT on rail, kilovoltage or megavoltage cone-beam CT (CBCT) and helical megavoltage CT. The verification of the accurate treatment position in conjunction with detailed anatomical information before every fraction can be essential for the outcome of the treatment. In this paper we present the on-board imager (OBI, Varian Medical Systems, Palo Alto, CA) that has been in routine clinical use at the Karolinska University Hospital since June 2004. The OBI has been used for on-line set-up correction of prostate patients using internal gold markers. Displacements of these markers can be monitored radiographically during the treatment course and the registered marker shifts act as a surrogate for prostate motion. For this purpose, on-board kV-kV seems to be an ideal system in terms of image quality. The CBCT function of OBI was installed in March 2005 at our department. It focuses on localizing tumors based on internal anatomy, not just on the conventional external marks or tattoos. The CBCT system provides the capacity for soft tissue imaging in the treatment position and real-time radiographic monitoring during treatment delivery.
机译:图像引导放射疗法(IGRT)可用于在治疗即将交付之前或期间测量和纠正目标和关键结构的位置误差。用于目标定位的最新方法包括:腹部超声,在室内MV或kV X射线中植入的标记物,光学表面跟踪系统,可植入的电磁标记物,在室内CT中(例如在铁路,千伏或兆伏圆锥上的kVCT)束CT(CBCT)和螺旋兆电压CT。在每一部分之前,结合详细的解剖学信息对准确的治疗位置进行验证对于治疗结果至关重要。在本文中,我们介绍了自2004年6月起已在卡罗林斯卡大学医院进行常规临床使用的车载成像仪(OBI,瓦里安医疗系统,加利福尼亚州帕洛阿尔托)。OBI已用于在线设置使用内部金标记物校正前列腺患者。这些标记的位移可在治疗过程中进行射线照相监测,所记录的标记位移可作为前列腺运动的替代物。为此,就图像质量而言,车载kV-kV似乎是理想的系统。 OBI的CBCT功能已于2005年3月在我们部门安装。它着重于根据内部解剖结构定位肿瘤,而不仅仅是常规的外部标记或纹身。 CBCT系统提供了在治疗位置进行软组织成像以及在治疗过程中进行实时射线照相监控的功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号