Tensile and knot properties of new generation (polyblend) and traditional suture materials in orthopedic surgery were investigated in standard laboratory conditions. Study focused on Fiberwire No. 5 and 2, Ethibond No. 5, 2 and 00, Orthocord No. 2, MaxBraid No. 2, Prolene No. 0 and 00, PDS No. 0 and 00, and Vicryl No. 2, 0 and 00. A 27-cm suture loop was fastened with 10 knots for ten samples for each type. Test parameters were tensile load to failure, elongation at failure point and knot slippage, and volume of 10-fold knots. Results were compared using ANOVA test. Failure load of No. 5 Fiberwire (625.0 +/- 30.0 N) was significantly higher compared to all other suture types. Tensile strengths of MaxBraid No. 2 (287 +/- 11 N) was significantly stronger compared to two other No. 2 polyblend sutures types and Ethibond No. 5. Knot slippage of Fiberwire No. 5 (14 +/- 1.9 mm) was significantly higher compared to all other suture types. Ethibond No. 2 (0.1 +/- 0.3 mm) had the lowest knot slippage. Elongation at the failure point of Fiberwire No. 2 (5%) was significantly lower than all other suture types. Mean calculated knot volume of #5 Fiberwire (73 +/- 6.9 mm(3)) was significantly higher compared to #5 Ethibond (53 +/- 4.8 mm(3)). Results of the study proved presence of significant differences between tensile and knot properties of various suture types and sizes. Loop security of larger diameter sutures is not always higher than thinner sutures. Suture elongation and knot slippage are important failure modes for high-diameter sutures and short-suture loops.
机译:在标准实验室条件下,研究了整形外科手术中新一代(复合材料)和传统缝合材料的拉伸和打结特性。研究集中在5号和2号光纤线,5号,2号和00号线,2号Orthocord,2号MaxBraid线,0号和00号针,0号和00号PDS以及2号,0号Vicryl线和00。每种类型的十个样品用10节的速度固定一个27厘米的缝合环。测试参数为破坏的拉伸载荷,破坏点的伸长率和结节滑移以及结节的10倍体积。使用ANOVA检验比较结果。与所有其他缝合线类型相比,第5根光纤丝(625.0 +/- 30.0 N)的破坏载荷明显更高。 MaxBraid 2号(287 +/- 11 N)的拉伸强度比其他2种2号混纺缝线和Ethibond 5号的抗拉强度明显强。与所有其他缝线类型相比,明显更高。第2号种族(0.1 +/- 0.3毫米)的打结滑移率最低。 2号wire丝断裂点的伸长率(5%)显着低于所有其他缝线类型。与#5 Ethibond(53 +/- 4.8 mm(3))相比,#5纤维线的平均计算结节体积(73 +/- 6.9 mm(3))明显更高。研究结果证明了不同类型和尺寸的缝合线的抗张结特性之间存在显着差异。大直径缝合线的环行安全性并不总是比薄缝合线高。缝线伸长和结节滑移是大直径缝线和短缝线环的重要破坏模式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号