INTRODUCTION: Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. METHODS: Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. RESULTS: Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory.
机译:简介:通常通过使用解剖标志物和与目标肌肉的自愿激活相关的听觉反馈来确保针头肌电图的准确性;但是,在某些临床情况下,地标可能无法触及,听觉反馈可能受到限制或不存在,并且针对特定肌肉可能更为关键。在这种设置下,图像引导可能会大大提高准确性。方法:两名经验不同的肌电图检查者对4个新鲜冷冻的尸体下肢中的每个肢体中的14条肌肉进行了检查。每条肌肉总共进行了八次测试。在没有超声(US)指导的情况下插入了四根细线,在US指导下插入了四根细线。计算了各个肌电图仪的总体准确度以及准确率。结果:非引导式针头放置的准确性明显低于美国引导式针头放置,特别是在经验不足的肌电图仪专家的手中,这支持在肌电图实验室在某些挑战性情况下使用实时美国指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号