摘要

The national primary standard for the number concentration of liquid-borne particles in the 10 to 20 (mu)m diameter range has been developed at the National Institute of Advanced Industrial Science and Technology (AIST), Japan. The standard consists of a total number counting type flow cytometer (T-FCM) and an electronic balance. The T-FCM is a commercial flow cytometer modified so that the total number of particles in an aqueous suspension sampled in a test tube can be counted, and the electronic balance is used to determine the mass of the suspension. This standard is intended to be used for calibrating commercial standard suspensions of monodisperse polystyrene latex (PSL) particles. The measurand in the calibration is the mass-based number concentration (the particle number in a unit mass of a suspension), and the calibration capability covers the concentration range from 5 X 10~(2) to 2 X 10~(6) particles g~(-1). When the concentration of the suspension is higher than 2 X 10~(3) particles g~(-1), the suspension is first diluted to about 1 X 10~(3) particles g~(-1) to suppress the coincidence loss in particle counting by the T-FCM. The validity of the calibration with the T-FCM was examined by comparison with an independent method in which a scanning electron microscope (SEM) was used to determine the number concentration of particles deposited on a silicon wafer. For a suspension of 10 (mu)m PSL particles with a concentration of approximately 1 X 10~(6) particles g~(-1), the concentration values determined by the T-FCM and SEM methods were 1.042 X 10~(6) and 1.035 X 10~(6) particles g~(-1), respectively: The difference was less than 0.7percent. The relative expanded uncertainty of the measurement by the T-FCM method with the coverage factor k velence 2 was 4.4percent.
机译:日本国立先进工业科学技术研究所(AIST)已制定了直径在10到20μm范围内的液体中颗粒物的数量浓度的国家主要标准。该标准包括总数计数型流式细胞仪(T-FCM)和电子天平。 T-FCM是一种经过改进的商品化流式细胞仪,可以对在试管中取样的水悬浮液中的颗粒总数进行计数,并使用电子天平确定悬浮液的质量。该标准旨在用于校准单分散聚苯乙烯胶乳(PSL)颗粒的商业标准悬浮液。校准中的被测量物是基于质量的数浓度(悬浮液的单位质量中的颗粒数),并且校准能力涵盖从5 X 10〜(2)到2 X 10〜(6)的浓度范围g〜(-1)。当悬浮液的浓度高于2 X 10〜(3)颗粒g〜(-1)时,首先将悬浮液稀释至约1 X 10〜(3)颗粒g〜(-1)以抑制重合损失。通过T-FCM进行颗粒计数。通过与独立方法进行比较,检验了使用T-FCM进行校准的有效性,在独立方法中,使用扫描电子显微镜(SEM)确定沉积在硅晶片上的颗粒数浓度。对于浓度约为1 X 10〜(6)g〜(-1)的10μmPSL颗粒的悬浮液,通过T-FCM和SEM方法确定的浓度值为1.042 X 10〜(6 )和1.035 X 10〜(6)粒子g〜(-1):差异小于0.7%。使用覆盖因子k velence 2的T-FCM方法进行测量的相对扩展不确定度为4.4%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号