首页> 外文期刊>Measurement >Measurement error in prism coupling method and refractive index profile reconstruction in ion-exchanged waveguides
【24h】

Measurement error in prism coupling method and refractive index profile reconstruction in ion-exchanged waveguides

机译:离子交换波导中棱镜耦合法的测量误差和折射率分布重建

获取原文
获取原文并翻译 | 示例
           

摘要

Measurement error in prism coupling method is studied and an analytic expression for the uncertainty of mode effective index measurement in an ion exchanged surface waveguide is derived. A novel algorithm to determine the profile of refractive index for ion-exchange waveguides is proposed. This method takes the values calculated by anti-WKB and linear segment interpolation as approximation and then uses the least squares fitting to eliminate the measurement error. Numerical results show that the proposed algorithm can effectively reconstruct the transverse refractive index profile of graded ion-exchange planar waveguides.
机译:研究了棱镜耦合法的测量误差,推导了离子交换表面波导模式有效折射率测量不确定度的解析表达式。提出了一种确定离子交换波导折射率分布的新算法。该方法将通过反WKB和线性段插值计算的值作为近似值,然后使用最小二乘拟合消除测量误差。数值结果表明,该算法可以有效地重构梯度离子交换平面波导的横向折射率分布。