The study of the hazard of electrostatic generation in pneumatic conveying systems was attempted by examining the sensitivity of electrical capacitance tomography (ECT) and the phenomena of spark generation due to strong electrostatics. The influence on ECT measurement accuracy of an electrostatic charge was analysed with reference to a switch capacitor configuration model. Consequently, it was found that the electrostatic charge introduced at the bend with sharp angles influenced the ECT results most significantly in pneumatic conveying systems, especially for the cases where a spark was generated. The investigation of spark generation indicated that a strong electrostatic charge can cause major discharges inside or outside the pipeline to damage the experimental instrument in severe cases.
机译:通过检查电容层析成像(ECT)的灵敏度以及由于强静电而产生火花的现象,试图研究气动输送系统中静电的危害。参考开关电容器配置模型,分析了静电荷对ECT测量精度的影响。因此,发现在弯曲处以锐角引入的静电荷在气动输送系统中对ECT结果的影响最大,特别是对于产生火花的情况。对火花产生的研究表明,在严重的情况下,较强的静电荷会导致管道内部或外部的大量放电损坏实验仪器。