Partial discharges (PD) in a power system component is a sever threat, indicating a high likelihood of the imminent and complete failure of the insulation. The reliability of partial discharge diagnostics depends upon the design and accuracy of the measuring sensors. In this paper the Rogowski coil is employed as a PD measuring sensor. The selection of suitable geometrical parameters has been identified as an important aspect regarding the proper operation and installation of the coil around the under test power component. These parameters significantly affect the measuring performance of the coil in terms of its sensitivity and bandwidth. The measurement performance of different geometrical designs for the high frequency Rogowski coils is evaluated. The variation in parameters such as core and coil diameter, diameter of the copper wire used for winding and number of turns, has been experimentally investigated. In addition the return winding, as a nonconventional method of creating a return loop for the Rogowski coil, is compared with a return wire (loop) to analyze sensor performance. The comparative study of variation in mechanical design features provides a brief guideline to select the optimal design of the coil.
机译:电力系统组件中的局部放电(PD)是严重威胁,表明绝缘即将完全失效的可能性很高。局部放电诊断的可靠性取决于测量传感器的设计和准确性。本文将Rogowski线圈用作PD测量传感器。合适的几何参数的选择已被确定为关于被测功率部件周围的线圈的正确操作和安装的重要方面。这些参数在灵敏度和带宽方面都会显着影响线圈的测量性能。评估了高频Rogowski线圈不同几何设计的测量性能。已经通过实验研究了诸如铁芯和线圈直径,用于缠绕的铜线的直径以及匝数之类的参数的变化。此外,作为为Rogowski线圈创建回路的一种非常规方法,将回路绕组与回路导线(回路)进行比较,以分析传感器性能。机械设计特征变化的比较研究为选择线圈的最佳设计提供了简要指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号