首页> 外文期刊>Makara Journal of Technology >Neutron Irradiation on SS316 Material for Radioactive Endovascular Stent Production
【24h】

Neutron Irradiation on SS316 Material for Radioactive Endovascular Stent Production

机译:

获取原文
获取原文并翻译 | 示例
           

摘要

It was reported that restenosis could be prevented by radioactive endovascular stent. SS316 material of endovascular stent has been irradiated at pneumatic rabbit system of G.A. Siwabessy reactor for 5 minutes for producing radioactive stent by neutron activation. After 10 days of decay, the irradiated SS316 was measured by gamma spectrometer. The radioisotopes of Cr-51, Fe-59 and( 60)Co were detected in the irradiated SS316 with radioactivity of 5990, 107 and 109 Bq/mg respectively. The Calculation results showed that radioisotopes of Cr-51, Fe-59 and( 55)Fe were produced by neutron activation. The radioactivity of Cr-51, Fe-59 and Fe-55 were 6051, 70 and 110 Bq/mg respectively. In the irradiated materials, the Fe-55 was not detected because the radioisotope emitted radiation with very low energy (5.9 keV). It is considered that radioisotope of Co-60 was produced from cobalt impurity in the SS316.