摘要

Bubble size distributions were measured at different locations in a 2.8 m~3 portable industrial scale sub-aeration flotation cell, treating zinc cleaner feed in the Hellyer Concentrator in Tasmania, Australia. The cell was fitted in turn with four different impeller-stator systems, and operated over a range of air flow rates and impeller speeds. The mean bubble size was found to increase with increase in air flow rate at different locations in the cell, for all four impellers, and to decrease with increase in impeller speed. The mean bubble size was largest close to the impeller shaft and smallest at the impeller discharge point, for all the impellers. The shape of the bubble size distribution also changed with location in the cell. The "global mean" bubble size calculated by simple arithmetic average of the values at six locations in the cell coincided remarkably well with the mean bubble size measured halfway between the impeller shaft and the side of the cell, at the top of the pulp. In general, the impellers produced "global mean" values of 1.0 mm or less at the manufacturer's recommended impeller speed.
机译:在澳大利亚塔斯马尼亚州Hellyer选矿厂处理2.8 m〜3便携式工业规模亚曝气浮选池中不同位置的气泡大小分布,对锌清洁剂进料进行处理。该单元依次装有四个不同的叶轮-定子系统,并在一定的空气流速和叶轮速度范围内运行。对于所有四个叶轮,发现平均气泡尺寸随单元中不同位置的空气流量的增加而增加,并随叶轮速度的增加而减小。对于所有叶轮,平均气泡尺寸在叶轮轴附近最大,而在叶轮排放点最小。气泡大小分布的形状也随单元中位置的变化而变化。通过对单元中六个位置的值进行简单算术平均值计算得出的“整体平均”气泡大小,与在纸浆顶部叶轮轴和单元侧面之间中途测得的平均气泡大小非常吻合。通常,叶轮在制造商建议的叶轮速度下产生的“全局平均值”值为1.0毫米或更小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号