...
首页> 外文期刊>European Journal of Surgical Oncology: The Journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology >The accuracy of digital infrared imaging for breast cancer detection in women undergoing breast biopsy.
【24h】

The accuracy of digital infrared imaging for breast cancer detection in women undergoing breast biopsy.

机译:数字红外成像在进行乳房活检的女性中检测乳腺癌的准确性。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Mammography has a lower sensitivity for breast cancer detection in younger women and those with dense breasts. Recent improvements in digital infrared breast imaging suggest there may be a role for this technology and we have studied its performance in 100 women prior to breast needle core biopsy (CB). METHODS: All patients were imaged using a digital infrared breast (DIB) scan (Sentinel BreastScan) prior to breast biopsy. Analysis of the infrared scans was performed, blinded to biopsy results, in four different ways: Sentinel screening report, Sentinel artificial intelligence (neural network), expert manual review and NoTouch BreastScan a novel artificial intelligence programme. RESULTS: Of 106 biopsies performed in 100 women, 65 were malignant and 41 were benign. Sensitivity of Sentinel screening (53%) and Sentinel neural network (48%) was low but analysis with NoTouch software (70%) was much closer to expert manual review (78%). Sensitivity (78%) and specificity (75%) using NoTouch BreastScan were higher in women under 50 and the combination of mammography and DIB, with NoTouch interpretation, in this age group resulted in a sensitivity of 89%. CONCLUSION: DIB using NoTouch is an effective adjunctive test for breast cancer detection in women under 70 and appears to be particularly effective in women under 50 where maximal sensitivity (78%) and specificity (75%) were observed. The combined sensitivity of NoTouch BreastScan and mammography in women under 50 was encouraging at 89%, suggesting a potential way forward for a dual imaging approach in this younger age group.
机译:背景:乳房X线照相术对年轻女性和乳房密实女性的乳腺癌检测敏感性较低。数字红外乳腺成像的最新进展表明,这项技术可能发挥了作用,我们已经在100例女性进行乳腺针芯活检(CB)之前对其进行了研究。方法:对所有患者在进行乳房活检之前均使用数字红外乳房(DIB)扫描(Sentinel BreastScan)进行成像。红外扫描的分析以四种不同的方式进行,对活检结果不知情:哨兵筛查报告,哨兵人工智能(神经网络),专家手册审核和新型人工智能程序NoTouch BreastScan。结果:在100例女性中进行的106例活检中,恶性65例,良性41例。 Sentinel筛查(53%)和Sentinel神经网络(48%)的敏感性较低,但使用NoTouch软件进行分析(70%)更加接近专家手册审查(78%)。在50岁以下的女性中,使用NoTouch BreastScan的敏感性(78%)和特异性(75%)更高,该年龄组的乳房X线照片和DIB结合NoTouch解释显示,敏感性为89%。结论:使用NoTouch的DIB是70岁以下女性乳腺癌的一种有效辅助检测方法,在50岁以下女性中特别有效,观察到最大敏感性(78%)和特异性(75%)。 50岁以下女性的NoTouch BreastScan和乳房X线摄影检查相结合的敏感性令人鼓舞,达到89%,这表明在这一年轻年龄组中双重成像方法的潜在发展方向。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号