Determination of the total iron by chitosan-modified glassy carbon electroe

机译:壳聚糖修饰的玻碳电极测定总铁

获取原文
获取原文并翻译 | 示例
       

摘要

Anew preconcentration and voltammetric method was developed for the determination of total Fe by a chitosan modified glassy carbon e.Iectrode (CMGCE). The measuremenl~ were carried out bJ cathodic stripping voltammetry. Using the instability of Fe(C_2O_4)j- to light and the reductive effect of C2O4-, the method can be used to determinate total iron. The effects of several experimental parameters, such as pH, the concentration of the modifier, deposition potential, deposition time, scan rate and UV absorption curves were studied for analytical applications. A linear response was obtained in the concentration range 2 X 10--11-3 X 10-7 g/m) Fe with a detection limit of 1 x 10 -ii g/ml for a 2-min deposition time. A relative standard deviation (R.S.D.) of 3.67% was obtained for six determinations of 2 X 10-7 g/ml Fe3+. The method can be used to determine the total iron in tap water and mineral water directly.
机译:开发了一种新的预浓缩和伏安法测定壳聚糖修饰的玻碳电极(CMGCE)中的总铁。测量是通过阴极溶出伏安法进行的。利用Fe(C_2O_4)j-对光的不稳定性和C2O4-的还原作用,该方法可用于测定总铁。研究了几个实验参数的影响,例如pH,改性剂的浓度,沉积电位,沉积时间,扫描速率和紫外线吸收曲线,以用于分析应用。在2 X 10--11-3 X 10-7 g / m Fe的浓度范围内获得了线性响应,在2分钟的沉积时间内检出限为1 x 10 -ii g / ml。六次测定2 X 10-7 g / ml Fe3 +的相对标准偏差(R.S.D.)为3.67%。该方法可直接测定自来水和矿泉水中的总铁。