首页> 美国卫生研究院文献>International Journal of Analytical Chemistry >Electrochemical Characterization of Iron (III) Doped Zeolite-Graphite Composite Modified Glassy Carbon Electrode and Its Application for AdsASSWV Determination of Uric Acid in Human Urine
【2h】

Electrochemical Characterization of Iron (III) Doped Zeolite-Graphite Composite Modified Glassy Carbon Electrode and Its Application for AdsASSWV Determination of Uric Acid in Human Urine

机译:铁(Ⅲ)掺杂的沸石-石墨复合修饰玻碳电极的电化学表征及其在adsASSWV测定人尿中尿酸中的应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Iron (III) doped zeolite/graphite composite modified glassy carbon electrode was prepared for determination of uric acid in human urine samples. Electrochemical impedance spectroscopic and cyclic voltammetric results confirmed surface modification of the surface of glassy carbon electrodes. Appearance of oxidative peak current with an over threefold enhancement at significantly reduced overpotential for uric acid at the composite modified electrode relative to the unmodified and even graphite modified electrode confirmed the electrocatalytic property of the composite towards electrochemical oxidation of uric acid. Under optimized method and solution parameters, linear dependence of peak current on uric acid concentration in a wide range of 1-120 μM, low detection limit value (0.06 μM), replicate results with low RSD, and excellent recovery results (96.61-103.45%) validated the developed adsorptive anodic stripping square wave voltammetric (AdsASSWV) method for determination of uric acid even in aqueous human urine samples. Finally, the developed composite modified electrode was used for determination of uric acid content in human urine samples collected from three young male volunteers. While the uric acid level in the urine samples from two of the studied volunteers was within the normal range, of the third was under the normal range.
机译:制备了铁(III)掺杂的沸石/石墨复合改性玻璃碳电极,用于测定人尿液中的尿酸。电化学阻抗谱和循环伏安法结果证实了玻璃碳电极表面的表面改性。相对于未改性的甚至是石墨改性的电极,在复合物修饰的电极上尿酸的过电位显着降低的情况下,氧化峰值电流以三倍以上的增强出现,证实了复合物对尿酸的电化学氧化的电催化性能。在优化的方法和溶液参数下,峰值电流对尿酸浓度的线性依赖性在1-120μM的范围内,低检测极限值(0.06μM),具有低RSD的重复结果和出色的回收率(96.61-103.45% )验证了开发的吸附阳极溶出方波伏安法(AdsASSWV)甚至在人尿液水溶液中也能测定尿酸。最后,开发的复合修饰电极用于测定从三名年轻男性志愿者收集的人类尿液样品中的尿酸含量。来自两名研究志愿者的尿液样本中的尿酸水平在正常范围内,而第三名志愿者在正常范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号