The pumping speed of a pump in an orifice flow standard was measured to enable calculation of the effective pumping speed in the calibration chamber. The main problems are as follows. (1) The pumping speed of a pump connected to a chamber of finite size is not unambiguously defined; different measuring arrangements lead to different values. It is necessary to measure the pumping speed of the pump in the same arrangement as for the orifice flow standard. (2) If this is to be a primary standard, gauges related to calibration of the gauge to another standard cannot be used for the measurement for the same range of pressures. The necessary precision of the measurement was determined. The orifice method and the flowmeter method were tested directly in the arrangement for the orifice flow standard. These two methods were used to avoid the necessity of using gauges calibrated to another standard. The pumping speed of the pump for the CMI orifice flow standard was measured with sufficiently low uncertainty, so that its effect on the uncertainty budget of the entire standard was negligible.
机译:测量孔口流量标准下的泵的泵速,以便能够计算出校准室内的有效泵速。主要问题如下。 (1)没有明确规定与有限尺寸的腔室相连的泵的抽速;不同的测量布置导致不同的值。必须以与节流孔标准相同的方式测量泵的抽速。 (2)如果将其作为主要标准,则不能在相同压力范围内使用与将压力表校准为另一标准相关的压力表。确定了必要的测量精度。孔板方法和流量计方法直接在孔板流量标准装置中进行了测试。使用这两种方法可以避免使用已校准为另一种标准的仪表的必要性。测量CMI孔口流量标准的泵的抽速时,不确定度要足够低,因此它对整个标准不确定度预算的影响可以忽略不计。