It is important to achieve correct orientation of an acetabular cup in order to avoid impingement, dislocation and increased wear. Cup orientation is usually assessed from a pelvis radiograph in which the central X-ray beam has been focused on the pubic symphysis. However, the angular offset of this beam from a beam passing through the centre of the cup causes rotational artefact in the cup image. Three simple algorithms for correcting this 3D rotational artefact are proposed, and these were validated using 3D CAD techniques by simulating the X-ray focus, target point and film position, as well as cup orientation. The accuracy of the correction was assessed in different practical scenarios. Cup version could be corrected to within a few hundredths of a degree, and inclination to within 0.2 degrees , if the X-ray target position was accurately located. However, only a small error in the correction was incurred if this position was erroneously located by as much as 10mm. The error in correcting the rotation position about the axis of symmetry depended on the cup size and anteversion setting, and it varied sinusoidally according to the position of measurement. Generally, it was within any possible measurement error. For the largest cup size considered (60mm outer diameter), the error ranged between -0.4 degrees and 0.8 degrees at the highest anteversion setting (30 degrees ).
机译:重要的是要确保髋臼杯的正确方向,以避免碰撞,脱位和增加磨损。杯定位通常是通过骨盆X射线照片评估的,其中中央X射线束已聚焦在耻骨联合上。然而,该光束与穿过杯的中心的光束的角度偏移导致在杯图像中的旋转伪像。提出了三种纠正此3D旋转伪像的简单算法,并通过模拟X射线焦点,目标点和胶片位置以及杯的方向,使用3D CAD技术对其进行了验证。在不同的实际情况下评估了校正的准确性。如果精确定位了X射线目标位置,则可以将杯形眼镜的角度校正到百分之几度以内,将倾斜度校正到0.2度以内。但是,如果此位置错误地定位了多达10mm,则只会产生很小的校正误差。校正围绕对称轴的旋转位置时的误差取决于杯的大小和前倾设置,并且会根据测量位置以正弦形式变化。通常,它在任何可能的测量误差范围内。对于所考虑的最大杯子尺寸(外径60mm),在最高前倾设置(30度)下,误差范围在-0.4度至0.8度之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号