The Fletcher Suit Delclos (FSD) ovoids employed in intracavitary brachytherapy (ICB) for cervical cancer contain shields to reduce dose to the bladder and rectum. Many treatment planning systems (TPS) do not include the shields and other ovoid structures in the dose calculation. Instead, TPSs calculate dose by summing the dose contributions from the individual sources and ignoring ovoid structures such as the shields. The goal of this work was to calculate the dose distribution with Monte Carlo around a Selectron FSD ovoid and compare these calculations with radiochromic film (RCF) and normoxic polymer gel dosimetry. Monte Carlo calculations were performed with MCNPX 2.5.c for a single Selectron FSD ovoid with and without shields. RCF measurements were performed in a plane parallel to and displaced laterally 1.25 cm from the long axis of the ovoid. MAGIC gel measurements were performed in a polymethylmethacrylate phantom. RCF and MAGIC gel were irradiated with four 33 microGy m2 h(-1) Cs-137 pellets for a period of 24 h. Results indicated that MCNPX calculated dose to within +/- 2% or 2 mm for 98% of points compared with RCF measurements and to within +/- 3% or 3 mm for 98% of points compared with MAGIC gel measurements. It is concluded that MCNPX 2.5.c can calculate dose accurately in the presence of the ovoid shields, that RCF and MAGIC gel can demonstrate the effect of ovoid shields on the dose distribution and the ovoid shields reduce the dose by as much as 50%.
机译:用于宫颈癌的腔内近距离治疗(ICB)中使用的Fletcher Suit Delclos(FSD)卵形体具有防护罩,可减少膀胱和直肠的剂量。许多治疗计划系统(TPS)在剂量计算中并未包括防护罩和其他卵形结构。取而代之的是,TPS通过汇总各个来源的剂量贡献并忽略卵形结构(如防护罩)来计算剂量。这项工作的目的是要计算Selectron FSD卵形周围的蒙特卡罗剂量分布,并将这些计算结果与放射致变色膜(RCF)和常氧聚合物凝胶剂量法进行比较。使用MCNPX 2.5.c对带有和不带有护罩的单个Selectron FSD卵形进行了Monte Carlo计算。在平行于卵形长轴并从卵形长轴横向偏移1.25 cm的平面上进行RCF测量。 MAGIC凝胶测量是在聚甲基丙烯酸甲酯模型中进行的。用四个33 microGy m2 h(-1)Cs-137颗粒辐照RCF和MAGIC凝胶24小时。结果表明,与RCF测量相比,MCNPX计算出的剂量在98%点的+/- 2%或2 mm以内,与MAGIC凝胶测量相比在98%的点计算+/- 3%或3 mm以内。结论是,MCNPX 2.5.c可以在存在卵形屏蔽的情况下准确计算剂量,RCF和MAGIC凝胶可以证明卵形屏蔽对剂量分布的影响,卵形屏蔽可以将剂量降低多达50%。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号