首页> 外文期刊>Medical Physics >Validation of K x-ray fluorescence bone lead measurements by inductively coupled plasma mass spectrometry in cadaver legs.
【24h】

Validation of K x-ray fluorescence bone lead measurements by inductively coupled plasma mass spectrometry in cadaver legs.

机译:尸体腿中电感耦合等离子体质谱法对K X射线荧光骨铅测量的验证。

获取原文
获取原文并翻译 | 示例

摘要

K x-ray fluorescence (KXRF) systems are being used in a growing number of epidemiologic studies to measure bone lead levels as a biological marker of accumulated lead exposure. Although validation of the KXRF technique in lead-doped phantoms and bare bone specimens has been repeatedly demonstrated, few studies have compared KXRF to chemical measurements of actual intact cadaver limbs (with skin and soft tissues). In this study, lead levels in eight amputated human legs were measured by KXRF; after dissection, levels in the bare bones were again measured by KXRF and then by inductively coupled plasma mass spectrometry (ICP-MS). We observed close agreement between the KXRF and ICP-MS measurements with correlation coefficients for both the tibia and patella greater than 0.9. In this study we provide further support for the validity of KXRF measurements, particularly with respect to the patella.
机译:K X射线荧光(KXRF)系统正在越来越多的流行病学研究中用于测量骨铅水平,作为累积铅暴露的生物标记。尽管已经多次证明了KXRF技术在掺杂铅的体模和裸露骨标本中的有效性,但很少有研究将KXRF与实际完整的尸体肢体(具有皮肤和软组织)的化学测量进行比较。在这项研究中,通过KXRF测量了8条被截肢的人类腿中的铅水平。解剖后,再次通过KXRF,然后通过电感耦合等离子体质谱(ICP-MS)测量裸骨中的水平。我们观察到KXRF和ICP-MS测量值之间的一致性,胫骨和骨的相关系数均大于0.9。在这项研究中,我们为KXRF测量的有效性提供了进一步的支持,尤其是在the骨方面。