PURPOSE: The correct assessment of energy expenditure (EE) in athletes is important to ensure that dietary energy intake is sufficient. In general, athletes are individuals with especially high levels of total EE (TEE) and exercise-related EE (ExEE). The SenseWear Pro3 Armband (SWA) is a multisensor device for the individual assessment of EE, but data on the validity for higher exercise intensities are missing. The aim of the study was to validate the SWA for the assessment of TEE and ExEE in endurance athletes. METHODS: The SWA was worn by 14 male endurance athletes for 7 d during a regular training period, and TEE was measured in parallel with the doubly labeled water method. Two controlled exercise trials (treadmill running=2.4-4.8 m.s, stationary bicycling=140-380 W) were performed, during which indirect calorimetry was used to assess ExEE. RESULTS: TEE assessed with the SWA and TEE measured with the doubly labeled water method were significantly correlated (r=0.73, P<0.01), but there were a proportional bias and considerably wide limits of agreement (-1368 to 1238 kcal.d). The error of TEE assessed with the SWA was related to the athletes' individual lactate thresholds (P<0.05). During running and bicycling, ExEE was significantly underestimated for most exercise intensities, and the underestimation increased with exercise intensity (P<0.001). CONCLUSIONS: According to our results, the SWA does not provide valid results of TEE and ExEE in endurance athletes because of the underestimation of EE at higher exercise intensities. It seems necessary to develop exercise-specific prediction equations to improve EE measurements in athletes.
机译:目的:正确评估运动员的能量消耗(EE)对确保膳食能量摄入足够重要。通常,运动员是总EE(TEE)和与运动有关的EE(ExEE)含量特别高的人。 SenseWear Pro3臂带(SWA)是用于EE个体评估的多传感器设备,但是缺少有关较高运动强度有效性的数据。这项研究的目的是验证SWA评估耐力运动员的TEE和ExEE。方法:在常规训练期间,由14名耐力男运动员穿戴了7天的SWA,并与双标签水法平行地测量了TEE。进行了两项对照运动试验(跑步机运行= 2.4-4.8 m.s,固定骑行= 140-380 W),在此期间,间接热量法用于评估ExEE。结果:用SWA评估的TEE和用双标记水法测量的TEE显着相关(r = 0.73,P <0.01),但存在比例偏差和相当宽的一致性极限(-1368至1238 kcal.d) 。 SWA评估的TEE误差与运动员的个体乳酸阈值有关(P <0.05)。在跑步和骑自行车的过程中,大多数运动强度的ExEE均被低估了,而运动强度低估了ExEE(P <0.001)。结论:根据我们的结果,由于在较高的运动强度下会低估EE,因此SWA无法为耐力运动员提供TEE和ExEE的有效结果。似乎有必要开发针对运动的预测方程式,以改善运动员的EE测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号