首页> 外文期刊>Materials at High Temperatures >Results of a low cycle fatigue inter-laboratory comparison on 1CrMoNiV rotor steel at elevated temperature
【24h】

Results of a low cycle fatigue inter-laboratory comparison on 1CrMoNiV rotor steel at elevated temperature

机译:1CrMoNiV转子钢在高温下的低周疲劳实验室间比较结果

获取原文
获取原文并翻译 | 示例
           

摘要

Following an initial intercomparison investigation carried out under a VAMAS programme, a similarventure has been carried out on a single source of 1Cr rotor steel at 525°C at a single total strainrange of 0.5% and reversed strain rate of 6%/min (10~3/s). A key difference was that, for eachspecimen prior to testing at high temperature, bending measurements were performed at roomtemperature as a check on unixial alignment since this parameter had previously been suggested as asource of scatter in endurance. Fifteen laboratories participated in the comparison and 67 test resultshave been subjected to statistical analysis. There appeared to be no consistent effect of the magnitudeof bending strain but it is concluded that a minimum of five repeat tests are required from eachestablishment for meaningful analyses to be made.
机译:在根据VAMAS计划进行的初步比较研究之后,在525°C的单一来源1Cr转子钢上进行了类似的测试,单一总应变范围为0.5%,反向应变率为6%/ min(10〜 3 / s)。一个关键的区别是,对于每个样品,在高温下进行测试之前,都应在室温下进行弯曲测量,以检查单轴对准性,因为以前曾建议将此参数作为耐久力分散的来源。有15个实验室参加了比较,并对67个测试结果进行了统计分析。弯曲应变的大小似乎没有一致的影响,但可以得出结论,每个机构至少需要进行五次重复测试才能进行有意义的分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号