A whole lot of corrosion damage occurred in galvanized steel pipes used in hot water supply systems,showing copper-induced pitting corrosion. The damage were obviously caused by copperions whichmigrated from the braze of the heat exchangers into the water. Some tests were carried out todetermine the copper-concentrations entering the stagnating water.
机译:热水供应系统中使用的镀锌钢管发生了很多腐蚀损坏,表明铜引起的点蚀。损坏显然是由铜离子从热交换器的钎焊移入水中造成的。为了确定进入死水的铜浓度,进行了一些测试。