Power plants are one of the major industries suffering from severe erosion-corrosion (E-C) problems resulting in substantial losses. One way of tackling this problem is by the use of thermal spray coatings. In the current investigation a new emerging technique i.e. cold spray coating process was used to deposit Ni-20Cr and Ni-50Cr powder on SA 516 (grade 70) boiler steel. The bare as well as the coated steels were subjected to cyclic experimental studies, in the superheater zone of a coal fired boiler. Weight change, thickness loss, XRD, FE-SEM/EDS and X-ray mapping techniques were used to analyse the eroded-corroded specimens. The uncoated steel showed weight gain after exposure in the actual boiler environment, whereas, for the coated steels there was initial weight loss followed by negligible weight change. Based upon thickness loss data the cold-sprayed Ni-50Cr coating was found to provide better E-C resistance than the Ni-20Cr coating.
机译:发电厂是遭受严重腐蚀-腐蚀(E-C)问题并导致大量损失的主要行业之一。解决该问题的一种方法是使用热喷涂涂层。在目前的研究中,一种新兴技术,即冷喷涂工艺被用于在SA 516(70级)锅炉钢上沉积Ni-20Cr和Ni-50Cr粉末。在燃煤锅炉的过热器区域,对裸露的钢和涂层钢进行了循环实验研究。重量变化,厚度损失,XRD,FE-SEM / EDS和X射线成像技术被用于分析腐蚀腐蚀的样品。未经涂层的钢在实际锅炉环境中暴露后显示出重量增加,而对于涂层钢,则存在初始重量损失,随后重量变化可忽略不计。根据厚度损失数据,发现冷喷涂的Ni-50Cr涂层比Ni-20Cr涂层具有更好的耐E-C性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号