It is certainly a difficult task to evaluate new materials and coatings to be used for boilers in power plants, as conditions are extremely complex, comprising a highly erosive environment, high temperature, highly corrosive gases, and reactive deposits. In particular, early catastrophic failures, as well as higher degradation rates have been observed on different power plant boiler components when operating under atmospheres containing low levels of oxygen. These atmospheres are typical of low NO_x burners, and can be more corrosive than normal oxidizing conditions. The presence of a sulfidizing atmosphere as well as ash deposits present in boilers, are in part responsible of this accelerated damage. In this work, testing under a low oxygen atmosphere has been carried out on T22 and P92 uncoated and coated specimens. The atmosphere was equal to that measured in a Spanish coal-fired power plant (ENDESA, Compostilla, Leon) and the test temperature was 580℃. Tested coatings were slurry applied aluminides, as well as two HVOF sprayed coatings including a commercially deposited Cr_2C_3NiCr, and a newly developed Cr_2O_3-Cr composite coating. The specimens were covered with ash (taken from the plant) prior to testing. After testing, the uncoated substrates exhibited high thickness oxides with some sulfide inclusions whereas all tested coatings were very protective. Exposed samples of T22 tubes employed in the Compostilla power plants were analyzed and compared with the corresponding specimens tested in the laboratory. In both cases, the scales contained Fe_3O_4 and FeS but the sulfide content was significantly higher in the scale formed in the plant. Moreover, ash particles were found embedded in the both scales.
机译:评估用于发电厂锅炉的新材料和涂料无疑是一项艰巨的任务,因为条件极为复杂,包括高侵蚀性环境,高温,高腐蚀性气体和反应性沉积物。特别是,在含氧量低的环境下运行时,已观察到不同电厂锅炉部件的早期灾难性故障以及较高的降解率。这些气氛是低NO_x燃烧器的典型气氛,并且比正常的氧化条件更具腐蚀性。硫化气氛以及锅炉中灰烬的存在是造成这种加速损坏的部分原因。在这项工作中,已经在T22和P92未涂覆和涂覆的样品上在低氧气氛下进行了测试。大气温度与西班牙燃煤电厂(ENDESA,Compostilla,莱昂)的测量温度相同,测试温度为580℃。所测试的涂层是浆料涂覆的铝化物,以及两种HVOF喷涂涂层,包括商业沉积的Cr_2C_3NiCr和新开发的Cr_2O_3-Cr复合涂层。在测试之前,样品用灰烬(取自植物)覆盖。经过测试,未涂覆的基材表现出高厚度的氧化物,并带有一些硫化物夹杂物,而所有测试的涂层都具有很好的防护性。分析了天然肥料工厂中使用的T22管的暴露样品,并将其与实验室中测试的相应样品进行了比较。在这两种情况下,氧化皮均含有Fe_3O_4和FeS,但在工厂形成的氧化皮中硫化物含量明显更高。此外,发现灰烬颗粒都嵌入了两个水垢中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号