From 1994-1999 several protective coatings and weld overlays were evaluated in Hatfield's Ferry #2 boiler. This boiler is a universal pressure, once through, supercritical boiler rated at 550 MWe. It burns eastern bituminous coals with a sulfur content of about 2.2 percent. Prior to the tests the boiler was retrofitted with a low NO_x cell burner system (LNCB). During the first round of the testing mainly thermal spray coatings were tested, as expected corrosion rates were relatively low (<25 mils (0.62 mm)/yr). This expectation was based on laboratory corrosion testing as well as results from field testing in the first boiler retrofitted with a low NO_x cell burner system. However, corrosion rates were found to be at least 2-3 times higher than expected and the thermal spray coating provided inadequate protection. Thus a second panel containing weld overlays, and diffusion coatings in addition to the most promising thermal spray coatings was installed and tested for 2.5 yrs. Evaluation of the coatings and weld overlays confirmed that the durability of the thermal spray and diffusion coatings was generally inadequate in the most corrosive areas. Further testing is needed to confirm their suitability for less corrosive areas, although some promising results were obtained. The durability of weld overlays depended greatly on their chemical composition, but all showed measurable wear. Weld overlays with a Cr content less than 20 percent generally corroded quite rapidly. Weld overlays with Cr content above 20 percent had generally low corrosion rates. The best performing materials had projected life expectancies 2-3 times greater than that of the poorest performing material.
机译:从1994 - 1999年,在哈特菲尔德的渡轮#2锅炉中评估了几种保护涂层和焊接覆盖层。这款锅炉是一种普遍的压力,一旦通过,超临界锅炉额定在550米。它燃烧了东方沥青煤,硫含量约为2.2%。在测试之前,锅炉用低No_x Cell燃烧器系统(LNCB)改装。在第一轮测试期间,主要测试热喷涂涂层,随着预期的腐蚀速率相对较低(<25密耳(0.62mm)/ YR)。这种预期基于实验室腐蚀测试,以及通过低NO_X CELL燃烧器系统改装的第一锅炉中的现场测试结果。然而,发现腐蚀速率比预期的至少2-3倍,并且提供的热喷涂涂层不足。因此,除了最有前途的热喷涂涂层之外,还有焊缝覆盖的第二面板和扩散涂层,并测试2.5°。涂层和焊接覆盖物的评估证实,热喷涂和扩散涂层的耐久性通常在最腐蚀性区域中通常不足。尽管获得了一些有希望的结果,但需要进一步测试以确认它们对较少腐蚀性区域的适用性。焊缝覆盖的耐久性依赖于其化学成分,但都显示出可测量的磨损。焊接覆盖层,Cr含量小于20%,通常迅速腐蚀。焊接覆盖率高于20%的Cr含量通常具有低腐蚀速率。最好的表演材料预期预期预期比最贫穷的表演材料大2-3倍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号