At the Institute for Corrosion Protection (Institut fur Korrosionsschutz) in Dresden, the CaCl{sub}2 test was developed to test high-alloyed CrNiMo steels and NiCrMo alloys and was applied for pitting and crevice corrosion resistance tests of those materials and their weldments. This test was carried out as a potentiostatic test at 0.2V{sub}(SCE) in a solution of 4.5 mol/l CaCl{sub}2 with an initial pH value of 3.2. Investigations on the influence of filler material, heat treatment and varying heat inputs per unit length of the welds confirm the applicability of the test. With reference to the results from a round-robin test carried out by a study group of the GfKORR working committee Corrosion Protection of Iron and Steel (Korrosionsschutz von Eisen und Stahl) on material grade 2.4605 (alloy 59) and its weldments, the study group concludes that, in research projects, the CaCl{sub}2 test is a good test to characterise the localised corrosion behaviour of welded joints of high-alloyed CrNiMo steels and NiCrMo alloys. However, to use it as quality assurance test would be too complex and susceptible to individual measuring differences.
机译:在德累斯顿的腐蚀保护研究所(Institut fur Korrosionsschutz),开发了CaCl {sub} 2测试来测试高合金CrNiMo钢和NiCrMo合金,并将其用于这些材料及其焊件的耐点蚀和缝隙腐蚀试验。该测试是在4.5 mol / l CaCl {sub} 2的溶液中,在0.2V {sub}(SCE)下进行的恒电位测试,初始pH值为3.2。对填充材料,热处理和每单位焊缝长度的热量输入影响的研究证实了该测试的适用性。根据GfKORR工作委员会的研究小组对材料等级2.4605(合金59)及其焊接件进行的钢铁腐蚀防护(Korrosionsschutz von Eisen und Stahl)循环试验的结果,该研究小组结论是,在研究项目中,CaCl {sub} 2测试是表征高合金CrNiMo钢和NiCrMo合金焊接接头局部腐蚀行为的良好测试。但是,将其用作质量保证测试将太复杂并且容易受到各个测量差异的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号