首页> 外文期刊>Fresenius' Journal of Analytical Chemistry >Definitive method certification of clinical analytes in lyophilized human serum: NIST standard reference material (SRM) 909b
【24h】

Definitive method certification of clinical analytes in lyophilized human serum: NIST standard reference material (SRM) 909b

机译:冻干人血清中临床分析物的确定方法认证:NIST标准参考材料(SRM)909b

获取原文
获取原文并翻译 | 示例
           

摘要

The National Institute of Standards and Technology (NIST) has developed several Standard Reference Materials (SRMs) based on human serum. NIST SRM 909b, Human Serum, is a lyophilized human serum material with concentrations for seven organic and six inorganic analytes at two levels certified solely by definitive methods (DMs). This material provides the vehicle by which high precision, high accuracy measurements made with DMs at NIST can be transferred through the measurement hierarchy to other laboratories. Isotope dilution gas chromatographic-mass spectrometric (GC-IDMS) methods were applied to measure cholesterol, creatinine, glucose, urea, uric acid, triglycerides, and total glycerides. Thermal ionization isotope dilution mass spectrometry (TI-IDMS) was used for determination of lithium, magnesium, potassium, calcium, and chloride. In addition, chloride was determined by coulometry. providing a comparison between two DMs. Sodium, which lacks a stable isotope that would permit isotope dilution mass spectrometric (IDMS) measurement, was determined by gravimetry. SRM 909b includes certified values for total glycerides and triglycerides, which were not certified in the previous lot of this material (SRM 909a). Improvement in uniformity of vial fill weight in the production of SRM 909b resulted in smaller certified uncertainties over previous freeze-dried serum SRMs. Uncertainties at the 99% level of confidence for relative expanded uncertainty (%) for certification of the organic analytes on a mmol/L/g basis ranged from 0.44% for urea (level II) to 5.04% for glucose (level II). (In-house studies have shown glucose to be a relatively unstable analyte in similar lyophilized serum materials, degrading at about 1%, per year.) Relative expanded uncertainties (99% C.I.) for certification of inorganic analytes on a mmol/L/g basis ranged from 0.25% for chloride (level I) to 0.49% for magnesium (level II). [References: 30]
机译:美国国家标准技术研究院(NIST)已开发了几种基于人血清的标准参考物质(SRM)。 NIST SRM 909b,人血清,是一种冻干的人血清物质,其浓度仅通过定性方法(DM)认证,两种浓度的7种有机和6种无机分析物。这种材料提供了一种工具,通过该工具,可以将NIST DM进行的高精度,高精度测量通过测量层次结构传输到其他实验室。同位素稀释气相色谱质谱法(GC-IDMS)用于测量胆固醇,肌酐,葡萄糖,尿素,尿酸,甘油三酸酯和总甘油酯。热电离同位素稀释质谱法(TI-IDMS)用于测定锂,镁,钾,钙和氯化物。另外,通过库仑法测定氯化物。提供两个DM之间的比较。通过重量分析法测定了缺乏稳定同位素的钠,该稳定同位素无法进行同位素稀释质谱(IDMS)测量。 SRM 909b包括总甘油酯和甘油三酸酯的认证值,在此材料的先前批次中未认证(SRM 909a)。 SRM 909b生产中小瓶填充重量均匀性的提高导致与以前的冻干血清SRM相比,较小的认证不确定性。在以mmol / L / g为基准对有机分析物进行认证的相对扩展不确定度(%)的置信度下,不确定度在99%范围内,尿素(II级)为0.44%,葡萄糖(II级)为5.04%。 (内部研究表明,在类似的冻干血清材料中,葡萄糖是相对不稳定的分析物,每年降解约1%。)相对扩展的不确定性(99%CI),用于以mmol / L / g的无机分析物认证基本范围从氯化物的0.25%(I级)到镁的0.49%(II级)不等。 [参考:30]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号