首页> 外文期刊>Forensic science international >Forensic oral imaging quality of hand-held dental X-ray devices: comparison of two image receptors and two devices.
【24h】

Forensic oral imaging quality of hand-held dental X-ray devices: comparison of two image receptors and two devices.

机译:手持式牙科X射线设备的法医口腔成像质量:两个图像接收器和两个设备的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

Recently, different portable hand-held and battery-powered dental X-ray units have become available. Especially for forensic odontological purposes, they offer diverse advantages such as for use in disaster areas and crime-scene locations as also in autopsy rooms and mortuaries. For any application, the most important feature of these hand-held devices is the delivered image quality. The aim of this study is to evaluate the radiographic image quality acquired by two portable X-ray devices in combination with two types of image receptors and to compare the findings with the image quality of a standard intra-oral X-ray device. Eleven samples consisting of eight teeth, two dry skeletal specimens and one formalin-fixed mandible part were mounted on blocks for standardised (re)positioning. Radiological images were acquired with two hand-held (AnyRay 60 kVp, 0.02-4.00 mAs and NOMAD 60 kVp, 0.023-2.277 mAs) and one wall-mounted (MinRay 60/70 kVp 0.14-22.4 mAs) X-ray device combined with two image receptor systems (VistaScan phosphor storage plate (PSP) and SIGMA M CMOS Active Pixel technology sensor). The effect of X-ray source-to-object distance (SOD) was checked at 20 cm in conjunction with object to image receptor distances (OIDs) of 0.8 and 2.5 cm. For each parameter setup, the exposure times were run from low till high. An expert consent statement was achieved by agreement of four expert observers selecting the optimal images based on a developed four point quality rating system. Next, a selection of the images was assembled in a set of 198 observation screens and scored by seven observers. The observation screens were designed to compare observer scores, relations between devices, receptors and OIDs and images obtained from the different devices at equal exposure levels (mAs). All results were statistically analysed. Radiological image quality was significantly higher for phosphor plate compared with the CMOS digital receptor system (p<0.0001). Furthermore, a significantly superior image quality was obtained for OID=0.8 than for OID=2.5 (p=0.039). A significant difference in image quality between the three devices was also established (p=0.02). The present study demonstrated the feasibility of portable X-ray systems for forensic odontological applications based on rendering optimal image quality, provided an in vitro guideline of optimal parameter settings and offered a radiological image database usable in further research.
机译:最近,已经出现了不同的便携式手持式和电池供电的牙科X射线机。特别是对于法医牙齿学目的,它们具有多种优势,例如可用于灾区和犯罪现场,以及尸体解剖室和尸体房。对于任何应用,这些手持设备的最重要特征是所提供的图像质量。这项研究的目的是评估两个便携式X射线设备结合两种类型的图像接收器获得的放射线图像质量,并将发现的结果与标准口内X射线设备的图像质量进行比较。将由八颗牙齿,两个干骨骼标本和一个福尔马林固定的下颌骨部分组成的11个样品安装在块上,以进行标准化(重新)定位。用两个手持式(AnyRay 60 kVp,0.02-4.00 mAs和NOMAD 60 kVp,0.023-2.277 mAs)和一个壁挂式(MinRay 60/70 kVp 0.14-22.4 mAs)X射线设备采集放射图像两个图像接收器系统(VistaScan荧光粉存储板(PSP)和SIGMA M CMOS Active Pixel技术传感器)。在20 cm处检查X射线源到物体的距离(SOD)的影响,并结合0.8 cm和2.5 cm的物体到图像接收器的距离(OID)。对于每个参数设置,曝光时间从低到高运行。通过四个专家观察员的同意,达成了专家同意声明,该专家观察员基于已开发的四点质量评级系统选择最佳图像。接下来,在198个观察屏幕中集合了一组图像,并由7个观察者进行了评分。观察屏幕旨在比较观察者分数,设备,受体和OID之间的关系以及在相同的曝光水平(mAs)下从不同设备获得的图像。所有结果均经过统计学分析。与CMOS数字接收器系统相比,磷光板的放射图像质量明显更高(p <0.0001)。此外,与OID = 2.5相比,OID = 0.8可获得明显更好的图像质量(p = 0.039)。还确定了这三个设备之间的图像质量有显着差异(p = 0.02)。本研究证明了基于渲染最佳图像质量的便携式X射线系统在法医牙齿学应用中的可行性,提供了最佳参数设置的体外指南,并提供了可用于进一步研究的放射图像数据库。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号