首页> 外文期刊>Foot and ankle surgery >Biomechanical comparison of a lateral polyaxial locking plate with a posterolateral polyaxial locking plate applied to the distal fibula
【24h】

Biomechanical comparison of a lateral polyaxial locking plate with a posterolateral polyaxial locking plate applied to the distal fibula

机译:外侧多轴锁定板与应用于腓骨远端的后外侧多轴锁定板的生物力学比较

获取原文
获取原文并翻译 | 示例
       

摘要

Background: Polyaxial locking plates are becoming popular for the fixation of distal fibula fractures. This study establishes how construct stiffness and plate loosening, measured as range of motion, differs between lateral and posterolateral plate location. Methods: Seven matched pairs of cadaver fibulae were osteotomized in standardized fashion to produce a Weber type B distal fibula fracture. The fragments were fixated with an interfragmentary lag screw and polyaxial locking plates, with one fibula in each pair receiving a posterolateral anti-glide-plate, and the other a lateral neutralization-plate. In a biomechanical test, the bending and torsional stiffnesses of the constructs and the ranges of motion (ROM) were measured and subjected to a paired comparison. Results: The laterally plated group had a higher median (interquartile range) bending stiffness (29.2 (19.7)N/mm) and a smaller range of motion (2.06 (1.99)mm) than the posterolaterally plated group (14.6 (20.6)N/mm, and 4.11 (3.28)mm, respectively); however, the results were not statistically significant (pbending=0.314; pROM=0.325). Similarly, the torsional stiffness did not differ significantly between the two groups (laterally plated: 426 (259)Nmm/° posterolaterally plated: 248 (399)Nmm/° ptorsion=0.900). The range of motion measurements between the two groups under torsional loading were also statistically insignificant (laterally plated: 8.88 (6.30)mm; posterolaterally plated: 15.34 (12.64)mm; pROM=0.900). Conclusion: In biomechanical cadaver-model tests of Weber type B fracture fixation with polyaxial locking plates, laterally plated constructs and posterolaterally plated constructs performed without significantly difference. Therefore, other considerations, such as access morbidity, associated injuries, patient anatomy, or surgeon's preference, may guide the choice of plating pattern. Further clinical studies will be needed for the establishment of definitive recommendations. Clinical relevance: Information on the behavior of polyaxial locking plates is relevant to surgeons performing internal fixation of distal fibula fractures.
机译:背景:多轴锁定板在固定腓骨远端骨折方面正变得越来越普遍。这项研究确定了以运动范围衡量的结构刚度和钢板松动在侧板和后外侧板位置之间如何不同。方法:以标准化方式将七对匹配的尸体腓骨切骨,以产生韦伯B型远端腓骨骨折。用片段间拉力螺钉和多轴锁定板固定碎片,每对中的一条腓骨接受后外侧抗滑行板,另一侧向中和板。在生物力学测试中,测量了结构的弯曲和扭转刚度以及运动范围(ROM),并进行了成对比较。结果:与后外侧组(14.6(20.6)N / mm)相比,外侧组的弯曲中位数(四分位间距)高(29.2(19.7)N / mm),运动范围较小(2.06(1.99)mm)。毫米和4.11(3.28)毫米);但是,结果在统计上并不显着(pbending = 0.314; pROM = 0.325)。类似地,两组之间的扭转刚度也没有显着差异(横向镀:426(259)Nmm /°,后外侧镀:248(399)Nmm /°扭转= 0.900)。两组在扭转载荷下的运动测量范围在统计学上也无关紧要(侧面镀层:8.88(6.30)mm;后侧面镀层:15.34(12.64)mm; pROM = 0.900)。结论:在用多轴锁定板固定韦伯B型骨折的生物力学尸体模型试验中,侧向建造的结构和后外侧建造的结构没有明显差异。因此,其他考虑因素(例如进入发病率,相关伤害,患者解剖结构或外科医生的偏爱)可能会指导电镀方式的选择。建立明确的建议将需要进一步的临床研究。临床意义:有关多轴锁定板行为的信息与进行腓骨远端骨折内固定的外科医生有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号