...
首页> 外文期刊>Isokinetics and exercise science >The relationships between leg peak power and shot-put performance in national-level athletes
【24h】

The relationships between leg peak power and shot-put performance in national-level athletes

机译:国家级运动员下肢峰值力量与铅球成绩之间的关系

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

AIM: Was to study the relationships between leg peak power, leg muscle volume and Shot-put performance in trained shot-putter. METHODS: Twenty-three shot-putter participated in this study. Anthropometric measurements were carried out to estimate leg muscle volume. Leg peak power and others biomechanical parameters (maximal force, maximal velocity, optimal force, optimal velocity) were measured using leg force-velocity test on ergocycle Monark, and the Optojump device. The shot-put performances were measured during a simulated competition.RESULTS: We found significant correlations between peak power output (W) measured during leg force-velocity Test on ergocycle (PPO-Ergo) and muscle volume for men (r = 0.79, p < 0.01) and women (r = 0.72, p < 0.05). PPO-Ergo (W, W/kg) was significantly correlated with the vertical jump performance (r = 0.56, p < 0.05; r = 0.62, p < 0.01 respectively). Shot-put performance was significantly correlated with PPO-Ergo (W, W/kg) and maximal force (N) (r = 0.72, p < 0.001; r = 0.48, p < 0.05; r = 0.85, p < 0.001 respectively). PPO as estimated from the vertical jump using the Optojump system (PPO-Opto) was not correlated to shot-put performances.CONCLUSION: The correlation between PPO-Ergo and shot-put performance showed that the force-velocity Test on ergocycle constitute a useful tool assessing PPO and others biomechanical parameters in shot-putter athletes. However, the Optojump system seems to be not accurate for such subjects. Fat mass constitute probably the limiting factor in shut-putter during this test.
机译:目的:研究经训练的铅球运动员的腿部峰值功率,腿部肌肉体积与铅球表现之间的关系。方法:23个铅球运动员参加了这项研究。进行人体测量以估计腿部肌肉的体积。腿部峰值功率和其他生物力学参数(最大力,最大速度,最佳力,最佳速度)是使用ergocycle Monark上的腿部力量速度测试和Optojump设备进行测量的。结果:我们发现,在人体工程学自行车上的腿部力量速度测试(PPO-Ergo)进行的腿部力量速度测试期间测得的峰值功率输出(W)与男性的肌肉体积(r = 0.79,p <0.01)和女性(r = 0.72,p <0.05)。 PPO-Ergo(W,W / kg)与垂直跳跃性能显着相关(r = 0.56,p <0.05; r = 0.62,p <0.01)。铅球成绩与PPO-Ergo(W,W / kg)和最大力(N)显着相关(r = 0.72,p <0.001; r = 0.48,p <0.05; r = 0.85,p <0.001) 。使用Optojump系统(PPO-Opto)从垂直跳动估计的PPO与铅弹性能没有关系。结论:PPO-Ergo与铅弹性能之间的相关性表明,对人体工程周期进行力速测试是有用的评估铅球运动员PPO和其他生物力学参数的工具。但是,Optojump系统似乎不适用于此类对象。在此测试中,脂肪量可能构成了关闭推杆的限制因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号