We aerate stored grain for a number of reasons: To cool it. To maintain a uniform temperature throughout the grain mass. To dry it. To rewarm it in the spring. Because it's not legal to add moisture to grain in storage. Some basic rules of thumb applyin designing an aeration system. To start with, the amount of air you need for aeration varies according to what you're trying to accomplish: For cooling or warming grain that is already dry, you need 1/20 to 1/10 cfm per bushel stored. For holding wetgrain, you need 1/5 to 1/2 cfm per bushel. For drying down grain in storage, you need 1/2 to 1.0 cfm per bushel.
机译:我们对储存的谷物进行充气的原因有很多:进行冷却。在整个谷物中保持均匀的温度。晾干。在春季重新武装。因为将水分添加到谷物中是不合法的。一些基本的经验法则适用于设计曝气系统。首先,充气所需的空气量根据要达到的目的而变化:要冷却或加热已经干燥的谷物,每蒲式耳需要1/20至1/10 cfm。要保持湿粮,每蒲式耳需要1/5至1/2 cfm。为了使存储中的谷物干燥,每蒲式耳需要1/2至1.0 cfm。