A request was received by the company from a customer to evaluate studs that were backing out during automatic assembly into a hub. The M14 × 1.5 × 90 Double Ended Studs involved in the customer's request were assembled by initially installing them onto a drive socket and then driving them into a threaded hole in the hub. The stud is driven until the shoulder of the stud contacts the hub and a torque of 75 ft-lb (100 N-m) is achieved. The contact between the shoulder of the stud and the hub causes the first thread in the hub to distort creating a locking action between the stud and the top thread of the hub. The assembly tool automatically shuts off when 75 ft-lb torque is achieved. The operator then switches the tool to reverse to disengage the socket from the stud (see Figure 1).
机译:公司收到了客户的要求,要求评估在自动组装到轮毂期间退出的螺柱。根据客户的要求,将M14×1.5×90双头螺柱进行组装,方法是先将它们安装到驱动器插槽上,然后将其驱动到轮毂上的螺纹孔中。驱动双头螺栓,直到双头螺栓的肩部接触轮毂,并获得75 ft-lb(100 N-m)的扭矩。螺栓的肩部和毂之间的接触导致毂中的第一螺纹变形,从而在螺栓和毂的顶螺纹之间产生锁定作用。当达到75 ft-lb的扭矩时,组装工具会自动关闭。然后,操作员将工具向后切换,以使承窝与双头螺栓脱开(见图1)。