...
首页> 外文期刊>Gait & posture >Kinematic comparison of split-belt and single-belt treadmill walking and the effects of accommodation
【24h】

Kinematic comparison of split-belt and single-belt treadmill walking and the effects of accommodation

机译:皮带式和单皮带式跑步机运动学的比较以及调节的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: Instrumented treadmills are becoming increasingly more common in gait laboratories. Instrumented side-split treadmills allow the collection of forces under each foot during walking. However, there may be a tendency to increase the base of support when walking on these treadmills, influencing other frontal plane mechanics as well. Therefore, the purpose of this study was to examine the effect of walking on a side-split instrumented treadmill on base of gait and frontal plane kinematics of the lower extremity. Methods: Twenty subjects walked on both a split and a single-belt treadmill. Base of gait and frontal plane kinematic angles and variability data were recorded. A one-way ANOVA was used to determine differences between the single and split-belt conditions at baseline and following a 10. min accommodation on the split-belt. The relationships between the change in base of gait and change in each kinematic variable were also determined. Results: On average, the base of gait was 3.7 cm wider on the split-belt treadmill with a 4 mm gap between belts. No significant differences were observed in the mean values of lower extremity kinematics or kinematic variability at baseline or following the 10. min accommodation. However, the increase in base of gait was significantly related to a decrease in peak knee and hip adduction angles. Conclusion: The 4 mm gap between the treadmill belts significantly increased the mean base of gait in all subjects. This did not alter mean frontal plane kinematics. However, as base of gait increased, the tendency towards hip and knee abduction also increased.
机译:简介:跑步机在步态实验室中变得越来越普遍。配有仪表的侧开式跑步机可在步行过程中在每只脚下收集力量。但是,在这些跑步机上行走时,可能会增加支撑的基础,也影响其他前额面力学。因此,本研究的目的是检验在步态和下肢额叶运动学的基础上,在侧裂式仪器跑步机上行走的效果。方法:二十名受试者同时在分开式和单带式跑步机上行走。记录步态的基础和额面运动学角度以及变异性数据。使用单向方差分析确定基线时以及在分裂带上放置了10分钟后,单一和分裂带条件之间的差异。还确定了步态基础的变化与每个运动学变量的变化之间的关系。结果:平均而言,皮带式跑步机的步态底部宽3.7 cm,皮带之间的间隙为4 mm。在基线或10分钟适应后,下肢运动学或运动学变异性的平均值未观察到显着差异。然而,步态基础的增加与峰值膝关节和髋关节内收角的降低显着相关。结论:跑步机皮带之间的4毫米间隙显着增加了所有受试者的平均步态基础。这并没有改变平均额叶运动学。但是,随着步态基础的增加,髋关节和膝关节外展的趋势也会增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号