Gait dysfunction is a common functional complaint of clients who seek medical care. Gait dysfunction can be caused by musculoskeletal disorders such as osteoarthritis or fractures, or it can be caused by neuromuscular disorders such as multiple sclerosis or cerebrovascular accident. Decisions made by health care providers working with these clients could be enhanced by the availability of valid and reliable gait measurement. Valid and reliable gait measurement is possible with laboratory-based motion analysis systems, but these are not universally available. Several portable systems collect footfall data and provide a relatively inexpensive alternative to sophisticated motion analysis systems. However, data collected by these portable systems cannot be used with confidence because of the lack of verification of the validity and reliability of the data they collect about movement. This paper describes a novel method of examining test-retest reliability and concurrent validity that produces a signal withminimal variation. To produce repetitive distance and timing events, a cylindrical weight was rolled across the field of both the laboratory motion analysis system and the system to be evaluated. Measures of the weight's movement were taken simultaneously with both systems. A reference point was chosen to allow for comparison between the systems. The spatial measure that was compared between systems was the horizontal distance between successive repetitions of the reference point's vertical position. The temporal measure that was compared between systems was the time between successive repetitions of the reference point's vertical position. The method described in this paper provides a minimally variable repetitive signal that can be used to investigate concurrent validity of gait analysis systems.
机译:步态障碍是寻求医疗服务的患者的常见功能性疾病。步态功能障碍可能是由诸如骨骼关节炎或骨折之类的肌肉骨骼疾病引起的,也可能是由诸如多发性硬化症或脑血管意外之类的神经肌肉疾病引起的。有效和可靠的步态测量方法可以增强与这些客户一起工作的医疗保健提供者的决策。基于实验室的运动分析系统可以进行有效且可靠的步态测量,但这些方法并非通用。几个便携式系统收集行人数据,并为复杂的运动分析系统提供相对便宜的替代方案。但是,由于缺乏对他们收集的有关运动的数据的有效性和可靠性的验证,因此无法放心使用这些便携式系统收集的数据。本文介绍了一种新的检查重测信度和并发有效性的方法,该方法可产生变化最小的信号。为了产生重复的距离和计时事件,在实验室运动分析系统和要评估的系统的整个领域上都滚动了圆柱重物。两种系统同时测量了砝码的运动。选择一个参考点以允许在系统之间进行比较。系统之间比较的空间度量是参考点垂直位置的连续重复之间的水平距离。系统之间比较的时间量度是参考点垂直位置连续重复之间的时间。本文描述的方法提供了一个最小可变的重复信号,可用于研究步态分析系统的并发有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号