A reliability study of biomechanical foot function in psoriatic arthritis based on a novel multi-segmented foot model.

机译:基于新型多节段足部模型的银屑病关节炎生物力学足功能的可靠性研究。

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this study was to determine the within-and between-day reliability of spatio-temporal, plantar pressure, kinematic and kinetic measurements based on a novel, seven segment foot model applied in patients with Psoriatic Arthritis (PsA). Nine PsA patients and matched healthy adult controls underwent three-dimensional gait analysis on two occasions, one week apart using a seven segment foot model. A core-set of functional variables including inter-segment kinematics, kinetics, spatio-temporal and plantar pressure distribution were analysed using the coefficient of multiple correlation (CMC), Bland-Altman plots, intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). Results showed excellent within- and between-day reliability for intersegment kinematic and kinetic data patterns with CMC values typically greater than 0.950 in a clinically stable cohort of PsA patients. Between-day reliability ranged from poor to excellent for absolute CMC values. Corrected CMC values were consistently higher across all variables ranging from fair-to-good to excellent. ICC values indicated excellent reliability for discrete spatio-temporal, plantar pressure, and ankle moment and power variables for both groups. Reliability for ground reaction forces and kinematic discrete variables ranged from fair-to-good to excellent. Standard error of measurement values ranged from 0.7 degrees to 3.0 degrees for discrete kinematic variables across both groups with greater variability in the PsA patients. In conclusion, intersegment kinematics and kinetics as well as spatio-temporal and plantar pressure can be reliably measured in PsA patients using a novel seven segment foot model. Some discrete kinematic variables have poor reliability and should not be used in prospective cohort and intervention studies.
机译:这项研究的目的是基于适用于银屑病关节炎(PsA)患者的新型七段脚模型,确定时空,足底压力,运动学和动力学测量值的日内和日间可靠性。九名PsA患者和相匹配的健康成人对照组分别进行两次三维步态分析,每隔一周使用七段脚模型进行三维步态分析。使用多重相关系数(CMC),Bland-Altman图,组内相关系数(ICC)和测量(SEM)。结果显示,在临床稳定的PsA患者队列中,节间运动学和动力学数据模式具有出色的日间和日间可靠性,CMC值通常大于0.950。对于绝对CMC值,日间可靠性从差到极好。从公平到良好到优秀,所有变量的校正后CMC值始终较高。 ICC值表明两组的离散时空,足底压力以及脚踝力矩和功率变量均具有出色的可靠性。地面反作用力和运动学离散变量的可靠性范围从中到好到极好。两组运动学变量的离散运动变量测量值的标准误差范围为0.7度至3.0度,而PsA患者的变异性更大。总之,可以使用新型七段足模型在PsA患者中可靠地测量节间运动学和动力学以及时空和足底压力。一些离散的运动学变量的可靠性较差,不应在前瞻性队列研究和干预研究中使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号