The purpose of the present study was to examine vibratory patterns of the neoglottis and to ascertain the neoglottic conditions that could cause failure in tracheoesophageal shunt phonation. We studied 30 tracheoesophageal shunt speakers while using "trap-door" type voice prostheses. Videostroboscopy was undertaken to investigate vibratory patterns of the neoglottis during phonation of the sustained vowel sound /e/ in these patients. The voice qualities of the patients were judged perceptually. A regular neoglottic vibration was observed in 21 patients. Nine patients had irregular neoglottic vibrations. In this latter group, two patients had incomplete neoglottic closures with breathy voices, four patients had multiple contacts of several mucosal walls with rough voices, and three patients had tight neoglottic closures with strained voices. During stroboscopic evaluation of tracheoesophageal shunt phonation, regularity of the neoglottic vibration may be the most significant finding. These findings show that it is as important to evaluate neoglottic vibration in alaryngeal voicing as it is to study glottic vibration in laryngeal voicing. Stroboscopic examination may be a help to elucidate a cause of failure in cases of poor tracheoesophageal shunt speech.
机译:本研究的目的是检查新声门的振动模式,并确定可能导致气管食管分流发声失败的新声门情况。我们研究了30个气管食管并联扬声器,同时使用“活板门”式语音假肢。在这些患者中,进行持续连续的元音/ e /的发声过程中进行了电视频闪检查,以研究新声门的振动模式。对患者的声音质量进行感知判断。在21例患者中观察到正常的新声振动。 9例患者出现不规则的新声门振动。在后一组中,两名患者的新声门关闭不全,伴有呼吸音,四名患者的多个粘膜壁多次接触,伴有粗糙的声音,三名患者的新声门紧闭,伴有紧张的声音。在频闪评价气管食管分流发声过程中,新声门振动的规律性可能是最重要的发现。这些发现表明,评估喉咙发声中的声门振动与研究喉咙发声中的声门振动一样重要。在气管食管分流口语不佳的情况下,频闪检查可能有助于阐明失败的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号