The effect of force, timing, and location on bone-to-implant contact of miniscrew implants.

机译:力,时机和位置对微型螺钉植入物与骨骼之间的接触的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

This study was conducted to evaluate the effect of timing and force of loading, as well as implant location, on bone-to-implant contact (BIC) of loaded and control miniscrew implants (MSI). Using seven skeletally mature male beagle dogs, 1-2 years of age, followed over a 110 day period, a randomized split-mouth design compared immediate versus delayed loading, 50 versus 25 g loading, and 25 g loads in the maxilla versus the mandible. Mobility was evaluated using a 0-3 point scale before the MSIs were prepared for histological analysis. Histomorphometric analyses were performed under light microscopy using Metamorph software on undecalcified sections. The percentage BIC was measured at three levels (coronal, middle, and apical) of the MSI. BIC was compared statistically using pairwise Wilcoxon signed-rank tests. Mobility was detected in three of the 56 (5.4 per cent) MSIs. The mobile implants were all unloaded controls and showed no BIC. All remaining stable MSIs showed some BIC. However, variation in BIC was large, ranging from 2.2 to 100 per cent. There were no significant (P > 0.05) differences in BIC associated with timing of force application, amount of force applied, or implant location. There was a tendency for less BIC at the coronal level, but the differences between levels were not statistically significant. Within the limits of this study, it is concluded that the timing and amount of force at loading and location of implant placement do not affect BIC. Moreover, it appears that only limited amounts of osseointegration are necessary to ensure implant stability.
机译:进行这项研究的目的是评估加载时间和加载力以及植入物位置对加载和控制的微螺钉植入物(MSI)的骨对植入物接触(BIC)的影响。使用七只骨骼成熟的雄性比格犬,年龄1-2岁,在110天的时间里跟踪随访,随机分口设计比较了立即加载与延迟加载,上颌加载50 vs 25 g以及下颌加载25 g的情况。 。在准备MSI进行组织学分析之前,使用0-3点量表评估活动能力。使用Metamorph软件在光学显微镜下对未脱钙的切片进行组织形态计量学分析。在MSI的三个级别(冠状,中层和顶端)测量BIC百分比。使用成对的Wilcoxon符号秩检验对BIC进行统计学比较。在56个(5.4%)MSI中,有三个检测到了移动性。可移动的植入物都是未加载的对照,没有显示出BIC。所有其余的稳定MSI都显示了一些BIC。但是,BIC的差异很大,从2.2%到100%不等。 BIC与施力时间,施力量或植入物位置无明显差异(P> 0.05)。有在冠状动脉水平上减少BIC的趋势,但是水平之间的差异没有统计学意义。在本研究的范围内,得出的结论是,在植入物放置和位置时的力的时间和大小不会影响BIC。而且,似乎仅需有限量的骨整合即可确保植入物的稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号