Immediate loading of 2(all-on-2) versus 4 (all-on-4) implants placed with a flapless technique supporting mandibular cross-arch fixed prostheses: 1-year results from a pilot randomised controlled trial.

机译:立即用无瓣技术支撑下颌交叉弓固定假体的2个(全2)vs 4个(全4)植入物加载:一项随机对照试验的1年结果。

获取原文
获取原文并翻译 | 示例
       

摘要

To evaluate the outcome of 2 versus 4 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses. Sixty patients from two different centres were randomised: 30 to the allon- 2 group and 30 to the all-on-4 group according to a parallel group design. To be immediately loaded, implants had to be inserted with a minimum torque of 40 Ncm. Outcome measures were prosthesis and implant failures, complications, and marginal bone level changes. Flaps were raised in 18 patients. A total of 2 implants in 2 patients did not reach the planned insertion torque and were immediately replaced by larger diameter ones. One year after loading, no drop-out or implant failure occurred. Eight biomechanical complications occurred in the all-on-2 group versus 8 complications in the all-on-4 group. There were no statistically significant differences for complications between groups. There were no statistically significant differences for marginal peri-implant bone levels between the two groups (estimate of the difference = -0.16; 95%CI -0.40 to 0.08; P (ANCOVA) = 0.074), with both groups losing a statistically significant amount of marginal bone (0.74 mm for all-on-2 implants and 0.58 mm for all-on-4 implants). There were statistically significant differences between the two centres, with more bone being lost for the Bologna centre (0.26 mm versus 1.07 mm). These preliminary results, up to 1 year after loading, suggest that immediately loaded mandibular cross-arch fixed prostheses can be supported by only 2 dental implants. Longer followups (approximately 10 years) are needed to properly evaluate this therapeutic option.
机译:为了评估将2枚和4枚无瓣植入物植入完全无牙的下颌骨中并立即用金属树脂螺钉固定的交叉弓假体进行修复的效果。来自两个不同中心的60名患者被随机分组​​:根据平行组设计,第2组为30例,第4组为30例。为了立即加载,必须以最小40 Ncm的扭矩插入植入物。结果是假体和植入物失败,并发症和边缘骨水平变化。 18例患者皮瓣升高。 2位患者中总共2个植入物未达到计划的插入扭矩,并立即被较大直径的植入物所替代。加载一年后,未发生脱落或植入失败的情况。全2组发生8例生物力学并发症,而全4组发生8例并发症。两组之间的并发症没有统计学上的显着差异。两组之间的种植体周围骨水平没有统计学上的显着差异(估计差异= -0.16; 95%CI -0.40至0.08; P(ANCOVA)= 0.074),两组均下降了统计学显着性边缘骨(全2种植体为0.74毫米,全4种植体为0.58毫米)。两个中心之间存在统计学上的显着差异,博洛尼亚中心的骨丢失更多(0.26 mm对1.07 mm)。这些初步的结果,直到加载后1年,表明立即加载的下颌交叉弓固定假体只能由2个牙科植入物支持。需要更长的随访时间(约10年)才能正确评估该治疗方案。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号