首页> 外文期刊>Eye & contact lens >Comparison of tear film surface quality measured in vivo on water gradient silicone hydrogel and hydrogel contact lenses
【24h】

Comparison of tear film surface quality measured in vivo on water gradient silicone hydrogel and hydrogel contact lenses

机译:在水梯度硅胶水凝胶和水凝胶隐形眼镜上体内测量的泪膜表面质量的比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: Recently, a new water gradient silicone hydrogel material has been introduced for a daily disposable lens. The aim of this study was to assess, in vivo, the prelens tear film surface quality (TFSQ) of this new lens in comparison with that of another daily disposable lens from the same manufacturer. METHODS: Eleven subjects wore two pairs of hydrogel nelfilcon A and silicone hydrogel delefilcon A lenses in two nonconsecutive days. The noninvasive lateral shearing interferometry was used to analyze the prelens tear film and distinguish between different contact lens materials. Measurements were taken in natural blinking conditions after 6 hours of wear. Additionally, the subjective comfort was evaluated. RESULTS: The presence of both lenses resulted in a TFSQ reduction as compared with the bare eye condition. Statistically significant (Wilcoxon rank sum test, P<0.012) smaller change in TFSQ was introduced by the water gradient material than the high water content material. A statistically significant correlation between the TFSQ results of the two lenses was found (Pearson correlation coefficient R=0.8, P<0.003), indicating high linearity of the measurement methodology with respect to the tested lens material. The correlation of subjective comfort in lenses was lower and found to be insignificant (R=0.6, P>0.05). CONCLUSIONS: Although the prelens TFSQ is not always directly proportional to the lens water content, the results of the in vivo study showed that the new water gradient silicone hydrogel material impact less TFSQ as compared with its predecessor.
机译:目的:最近,一种新型的水梯度有机硅水凝胶材料被引入日常使用的镜片中。这项研究的目的是在体内评估该新镜片与同一制造商的另一种日常使用的一次性镜片的镜片撕裂膜表面质量(TFSQ)。方法:11名受试者在连续2天不戴2副水凝胶nelfilcon A和硅水凝胶delefilcon A镜片。使用非侵入性横向剪切干涉术来分析镜前泪膜并区分不同的隐形眼镜材料。佩戴6小时后,在自然眨眼条件下进行测量。另外,评估了主观舒适度。结果:与裸眼状况相比,两个镜片的存在都会导致TFSQ降低。具有统计意义的显着性(Wilcoxon秩和检验,P <0.012)由水梯度材料引入的TFSQ的变化要比高含水量的材料小。发现两个镜片的TFSQ结果之间具有统计学上的显着相关性(Pearson相关系数R = 0.8,P <0.003),表明测量方法相对于被测镜片材料具有高度线性。晶状体主观舒适度的相关性较低,且无统计学意义(R = 0.6,P> 0.05)。结论:虽然前镜片TFSQ并不总是与镜片含水量成正比,但体内研究结果表明,新型水梯度有机硅水凝胶材料对TFSQ的影响小于其前身。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号