AIM: To determine whether significant correlations exist between retinal sensitivity measured by fundus-related microperimetry and the visual acuity and the foveal thickness measured by optical coherence tomography (OCT) in eyes with diabetic macular edema (DME). METHODS: A retrospective chart review of 32 eyes with DME and 17 normal healthy eyes that had undergone fundus-related microperimetry and OCT. The macular sensitivity was measured using the recently introduced fundus-related microperimeter, Micro Perimeter 1. The mean retinal sensitivities within the central 2 degrees and 10 degrees were correlated with the best-corrected visual acuity and OCT-measured foveal retinal thickness. RESULTS: The mean sensitivities in the central 2 degrees and 10 degrees were significantly lower in patients with DME than in normal subjects (P<0.0001). The mean retinal sensitivities in the central 2 degrees and 10 degrees were inversely correlated with visual acuity (r(2)=0.623, P<0.0001; r(2)=0.581, P<0.0001) and foveal thickness (r(2)=0.581, P<0.0001; r(2)=0.551, P<0.0001). CONCLUSIONS: The mean retinal sensitivities measured with fundus-related microperimetry were significantly lower in eyes with DME than in normal eyes. Because a significant correlation of the microperimeter-determined retinal sensitivity to visual acuity and foveal thickness was observed, the retinal sensitivities obtained by fundus-related microperimetry may be another measure that can be used to assess the effects of DME.
机译:目的:确定在患有糖尿病性黄斑水肿(DME)的眼睛中,通过眼底相关的微孔测量法测量的视网膜敏感性与视力和光学相干断层扫描(OCT)测量的中央凹厚度之间是否存在显着相关性。方法:回顾性分析了32只DME眼和17只正常眼的健康眼,这些眼均经过了眼底相关的微视野检查和OCT检查。使用最近推出的眼底相关显微周长Micro Perimeter 1测量黄斑敏感度。中心2度和10度以内的平均视网膜敏感性与最佳矫正视力和OCT测量的中央凹视网膜厚度相关。结果:DME患者中枢2度和10度的平均敏感性明显低于正常受试者(P <0.0001)。中央2度和10度的平均视网膜敏感性与视力(r(2)= 0.623,P <0.0001; r(2)= 0.581,P <0.0001)和中央凹厚度(r(2)= 0.581,P <0.0001; r(2)= 0.551,P <0.0001)。结论DME眼的眼底相关微孔测量法测得的平均视网膜敏感性明显低于正常眼。因为观察到了微周边测定的视网膜敏感性与视敏度和中央凹厚度的显着相关性,所以通过眼底相关的微视野术获得的视网膜敏感性可能是另一种可用于评估DME疗效的措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号