首页> 外文期刊>European radiology >Higher lesion conspicuity for SENSE dynamic MRI in detecting hypervascular hepatocellular carcinoma: analysis through the measurements of liver SNR and lesion-liver CNR comparison with conventional dynamic MRI.
【24h】

Higher lesion conspicuity for SENSE dynamic MRI in detecting hypervascular hepatocellular carcinoma: analysis through the measurements of liver SNR and lesion-liver CNR comparison with conventional dynamic MRI.

机译:SENSE动态MRI在检测高血管性肝细胞癌中具有较高的病变显着性:通过与常规动态MRI相比,通过测量肝脏SNR和病变肝​​脏CNR进行分析。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of our study was to compare the signal-to-noise ratio (SNR) of liver parenchyma and the contrast-to-noise ratio (CNR) of hypervascular hepatocellular carcinoma (HCC) between conventional and SENSE dynamic MRI. Thirty-one consecutive patients who were strongly suspected of having HCC were enrolled in our study. The subjects consisted of 20 men and 11 women aged 52 years to 79 years (mean 66.8 years). Dynamic MRI was performed for each patient, with SENSE (SENSE MRI) and without SENSE (conventional MRI) on separate days. For the quantitative analysis, the liver SNR and the lesion-liver CNR of 25 hypervascular HCCs detected on both conventional and SENSE dynamic MRI were measured. The liver SNR of the arterial phase and the portal venous phase was 84.1+/-24.7 and 104.7+/-34.3, respectively, in conventional MRI, while it was 62.9+/-19.5 and 44.5+/-18.2, respectively, in SENSE MRI. SENSE MRI showed a statistically significantly lower SNR than conventional MRI (P<0.01). The lesion-liver CNR was 26.3+/-15.9 in conventional MRI and 39.0+/-19.6 in SENSE MRI. The lesion-liver CNR in SENSE MRI was significantly higher than in conventional MRI (P<0.01). The SNR in SENSE MRI is significantly lower than in conventional MRI, although the lesion CNR is significantly higher than in conventional MRI.
机译:我们的研究目的是比较常规和SENSE动态MRI之间的肝实质的信噪比(SNR)和高血管肝细胞癌(HCC)的对比噪声比(CNR)。连续31例强烈怀疑患有HCC的患者参加了我们的研究。受试者包括年龄介于52岁至79岁(平均66.8岁)的20名男性和11名女性。对每位患者进行动态MRI,分别在SENSE(SENSE MRI)和无SENSE(常规MRI)下进行。为了进行定量分析,测量了在常规和SENSE动态MRI上检测到的25种高血管HCC的肝SNR和病变肝​​脏CNR。在常规MRI中,动脉期和门静脉期的肝脏SNR分别为84.1 +/- 24.7和104.7 +/- 34.3,而SENSE分别为62.9 +/- 19.5和44.5 +/- 18.2核磁共振SENSE MRI的SNR在统计学上显着低于常规MRI(P <0.01)。在常规MRI中,病变肝脏CNR为26.3 +/- 15.9,在SENSE MRI中为39.0 +/- 19.6。 SENSE MRI的病灶CNR明显高于常规MRI(P <0.01)。尽管病变CNR明显高于常规MRI,但SENSE MRI中的SNR显着低于常规MRI。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号