...
首页> 外文期刊>European radiology >Magnetic resonance urography for the assessment of potential renal donors: comparison of the RARE technique with a low-dose gadolinium-enhanced magnetic resonance urography technique in the absence of pharmacological and mechanical intervention.
【24h】

Magnetic resonance urography for the assessment of potential renal donors: comparison of the RARE technique with a low-dose gadolinium-enhanced magnetic resonance urography technique in the absence of pharmacological and mechanical intervention.

机译:磁共振尿路造影用于评估潜在的肾脏供体:在没有药理学和机械干预的情况下,RARE技术与低剂量g增强磁共振尿路造影技术的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to determine whether magnetic resonance urography without pharmacological (diuretic) stimulation and mechanical compression allows conclusive evaluation of the urinary system in potential renal donors. In 28 consecutive patients magnetic resonance urography (MRU) was performed on a 1.5-T system. Two techniques, rapid acquisition with relaxation enhancement (RARE) and a gadolinium (Gd)-enhanced 3D fast low angle shot (FLASH) sequence were compared in the absence of adjunctive measures. Two reviewers assessed image quality, presence of artifacts and completeness of visualization of the collecting systems and ureters. Among the 53 MR urograms, there was no difference in image quality and presence of artifacts between RARE and Gd-MRU. Despite high image quality, visualization of the urinary collecting system was insufficient. Continuous visualization from the collecting system to the distal ureter was demonstrated bilaterally in only 14% of the RARE and 26% of Gd-enhanced MR urograms, respectively. Overall, Gd-enhanced MRU was superior to the RARE technique in displaying the segments of the urinary collecting system, but this difference was not found to be statistically significant. Neither the RARE technique nor the gadolinium-enhanced MRU technique is accurate enough to allow the evaluation of the collecting system and ureters in potential renal donors in the absence of pharmacological intervention and compression.
机译:这项研究的目的是确定没有药理(利尿剂)刺激和机械压迫的磁共振尿路造影术是否可以对潜在的肾脏供体中的泌尿系统进行结论性评估。在连续的28位患者中,在1.5-T系统上进行了磁共振尿路造影(MRU)。在没有辅助措施的情况下,比较了两种技术:松弛增强快速获取(RARE)和a(Gd)增强的3D快速低角度拍摄(FLASH)序列。两名评价者评估了图像质量,伪影的存在以及收集系统和输尿管的可视化的完整性。在这53个MR尿路图中,RARE和Gd-MRU之间的图像质量和伪像的存在没有差异。尽管图像质量高,但尿液收集系统的可视化仍不足。从采集系统到输尿管远端的连续可视化分别在双边的RARE和Gd增强的MR尿路造影中分别得到了14%和26%的证实。总体而言,Gd增强的MRU在显示尿液收集系统的各个部分方面优于RARE技术,但未发现此差异具有统计学意义。 RARE技术或nor增强的MRU技术都不够准确,无法在没有药理干预和压迫的情况下评估潜在肾供体中的收集系统和输尿管。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号