A shortcut review was carried out to establish whether ultrasonography was a reliable and accurate imaging modality to detect rotator cuff tears in adult patients. Four papers were found to be relevant to the clinical question following the below-described search strategies. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of those best papers are tabulated. It is concluded that ultrasound has a diagnostic accuracy high enough to detect full-thickness rotator cuff tears. It is, however, less accurate in detecting partial-thickness ruptures.
机译:进行了简短的回顾,以确定超声检查是否是检测成人患者肩袖撕裂的可靠且准确的影像学检查方法。按照以下描述的搜索策略,发现有四篇论文与临床问题相关。将这些最佳论文的作者,出版日期和国家,研究的患者组,研究类型,相关结果,结果和研究缺点制成表格。结论是超声具有足够高的诊断准确性,可以检测出全厚度肩袖撕裂。但是,它在检测局部厚度破裂方面的准确性较差。